# Project Tracker ID Source Status Priority Standard(s) Subject Updated
5929 IEC TC57 WG10 Future Work WG10 Future Work IEC 62361-102 R8 New Normal

IEC 61850-6

CIM-61850 Harmonization - allow Terminals with no connections - use explicit ConnectivityNode.name = None 02/08/2024 05:08 AM Actions
5930 IEC TC57 WG10 Future Work WG10 Future Work IEC 62361-102 R6 New Normal

IEC 61850-6

CIM-61850 Harmonization - mRID attribute in SCL for Equipment, Terminals, ConnectivitNodes 02/08/2024 05:08 AM Actions
5931 IEC TC57 WG10 Future Work WG10 Future Work IEC 62361-102 R3 New Normal

IEC 61850-6

CIM-61850 Harmonization - Add string attribute psrType to tPowerSystemResource. 02/08/2024 05:08 AM Actions
5932 IEC TC57 WG10 Future Work WG10 Future Work IEC 62361-102 R2 New Normal

IEC 61850-6

CIM-61850 Harmonization - Extend list of equipment type codes 02/08/2024 05:07 AM Actions
5927 IEC TC57 WG10 Future Work WG10 Future Work IEC 62361-102 R15 New Normal

IEC 61850-7-4

CIM-61850 Harmonization - Add PosFlwIn data object to measurement classes 02/08/2024 05:22 AM Actions
632 IEC 61850 User Feedback Task Force Support 8 H30 Resolved High

IEC 61850-9-2, IEC 61869-9

APPID 0x4000 - Sampled Values 12/05/2023 09:16 AM Actions
5091 IEC 61850 User Feedback Task Force Feature 10 H30 Resolved Normal

IEC 61850-2

Devices types/acronyms 06/05/2023 01:58 AM Actions
608 IEC 61850 User Feedback Task Force Feature 7 H30 In Progress Normal

IEC 61850-90-xx

Comprehensive set of requirements covering validation and supervision of all IEC 61850 communications 06/21/2022 02:09 AM Actions
607 IEC 61850 User Feedback Task Force Support 6 H30 In Progress Normal

IEC 61850-80-6 (90-2)

LPHD.Sim management 06/21/2022 02:09 AM Actions
605 IEC 61850 User Feedback Task Force Improvement 4 H30 In Progress Normal

IEC 61850-10-3

Test and Simulation mode questions 06/21/2022 02:09 AM Actions
556 IEC 61850 User Feedback Task Force Support 3 H30 In Progress Normal

IEC 61850-90-20

Rendundant CT/TT measurements 06/21/2022 02:09 AM Actions
555 IEC 61850 User Feedback Task Force Support 2 H30 Rejected Normal Link Failover reliability problem - implication to protection application 10/25/2022 09:01 AM Actions
554 IEC 61850 User Feedback Task Force Support 1 H30 Resolved Normal Performance requirement for SV and implications to Protection applications 05/09/2023 09:32 AM Actions
5933 IEC TC57 WG10 Future Work WG10 Future Work FNN Germany New Normal

IEC 61850-7-4

Proposal of a new LN class ASWI 02/08/2024 05:06 AM Actions
5876 IEC 61850 User Feedback Task Force Improvement FNN Germany Resolved Normal

IEC 61850-7-4 Ed.3

Proposal of a new LN class ASWI 06/05/2023 01:58 AM Actions
647 IEC 61850 User Feedback Task Force Support 57 ENTSO-E Resolved Normal

IEC 61850-7-500

Single phase and multi phase trip indication for the autorecloser 05/09/2023 09:32 AM Actions
580 IEC 61850 User Feedback Task Force Support 52 ENTSO-E Resolved Normal

IEC 61850-7-500

Voltage protection: Undervoltage protection - 3ph operate 05/09/2023 09:32 AM Actions
579 IEC 61850 User Feedback Task Force Support 51 ENTSO-E Resolved Normal

IEC 61850-7-500

Voltage protection: Overvoltage protection - 3ph operate 05/09/2023 09:32 AM Actions
572 IEC 61850 User Feedback Task Force Support 44 ENTSO-E Resolved Normal

IEC 61850-7-500

S/S related applications: Auxiliary circuit supervision 05/09/2023 09:32 AM Actions
6167 IEC 61850 User Feedback Task Force Support email Resolved Normal

IEC 61850-90-6

IEC 61850-90-6 Voltage presence CDC for SVPI.Prs 06/05/2023 01:58 AM Actions
6248 IEC 61850 User Feedback Task Force Improvement EDF Resolved Normal

IEC 61850-6

There are controls between IEDs for automatic control functions, we need to be able to represent those controls in SCL (for configuration in SCT, data flow documentation...) 06/14/2023 08:33 AM Actions
5966 IEC TC57 WG10 Future Work WG10 Future Work EDF New Normal Indicate typical SIUnit for every DO with CDC MV would help users + Add a dedicated attribute in NSD files instead of having it in the description ? 02/09/2024 04:02 AM Actions
5955 IEC 61850 User Feedback Task Force Improvement EDF Resolved Normal Indicate typical SIUnit for every DO with CDC MV would help users + Add a dedicated attribute in NSD files instead of having it in the description ? 06/05/2023 01:58 AM Actions
6703 IEC TC57 WG10 Future Work WG10 Future Work Ed 3 review New Normal

IEC 61850-7-4, IEC TS 61850-80-4

Part 80-4 Mapping to COSEM : add reactive and apparent energy data objects to MMTR and MMTN 02/09/2024 02:43 PM Actions
5335 IEC 61850 User Feedback Task Force Improvement Dustin Tessier Resolved Normal

IEC 61850-90-4

Adding Normative Requirements & Conformance Testing Pertaining to Broadcast Storms 06/05/2023 01:58 AM Actions
6684 61850-7-5 and 61850-7-500 IEC61850-7-5 discussion New Normal Proposal to deprecate 'LocSta' in X and Y group LN classes 01/22/2024 02:50 AM Actions
6185 IEC TC57 WG10 Future Work WG10 Future Work 2022 IOP New Normal

IEC 61850-6

SCL Need to differentiate the difference in the number of GOOSE vs R-GOOSE 10/26/2023 05:01 AM Actions
6175 IEC 61850 User Feedback Task Force Bug 2022 IOP In Progress Normal

IEC 61850-6

SCL SICS requires SNTP even with 2.1 where PTP is the preferred method. 11/07/2023 08:21 AM Actions
5970 IEC 61850 User Feedback Task Force Improvement 2022 f2F IOP In Progress Normal

IEC 61850-6

SCT behavior needs to be specified regarding mismatch between substation section and IED section 11/08/2022 08:24 AM Actions
5375 WG13 Issues CIM Issues In Progress Urgent Clean up transformer documentation - Margaret removed paragraphs from Part-11 and see where they fit [GMDM #5] (align xf descriptions in 61870-301, -457 and 61968-11, -13) 06/14/2023 09:49 AM Actions
6758 WG13 Issues CIM Issues New High Measurement issues 04/13/2024 12:42 AM Actions
6757 CIM Joint Issues CIM Issues New High BasicIntervalSchedule and RegularIntervalSchedule 05/09/2024 11:49 AM Actions
6752 WG14 Part 5 Issues CIM Issues New High Deprecate Part 5 Modelling 04/02/2024 10:49 AM Actions
6750 Server Issues Resolved High sAddr length - TISSUE 1885 04/16/2024 08:17 AM Actions
6749 Server Issues Resolved High Clarification of ExtRef attributes usage - TISSUE 1818 04/16/2024 08:31 AM Actions
6745 WG16 Issues CIM Issues Open High Need for consistent approach for Market Products 04/18/2024 10:41 AM Actions
6680 WG13 Issues CIM Issues New High

61970-456

Support time series/schedule for SSH 01/17/2024 10:19 AM Actions
6663 WG13 Issues CIM Issues Open High

IEC 61970-456

The SSH profile needs to be revisited and updated for consistency. 02/04/2024 12:14 AM Actions
6621 WG14 Issues CIM Issues Review High Add the Design sub-package to the Enterprise package 12/05/2023 01:41 PM Actions
6620 WG14 Issues CIM Issues New High Enterprise Package Name Related Model Updates 12/05/2023 01:07 PM Actions
6619 CIM Joint Issues CIM Issues New High

IEC61968-3 thru IEC61968-11, IEC61970-301, IEC62325-301

Renaming the CIM UML Model Packages 12/05/2023 12:37 PM Actions
6610 WG13 Issues CIM Issues New High

61970-301; 61970-452

Multiple issue Measurement and Control 11/27/2023 10:27 AM Actions
6584 CIM Joint Issues CIM Issues New High Handling unit multiplier needs joint WG concensus on approach 11/08/2023 07:03 AM Actions
6553 WG13 Issues CIM Issues New High Removal of InfGrid package InfSIPS 11/15/2023 10:48 AM Actions
6549 WG14 Part 9 Issues CIM Issues New High

61968-3, 61968-5, 61968-9

Switch Contention Issue 03/07/2024 10:38 AM Actions
6377 61850-7-5 and 61850-7-500 IEC61850-7-5 New High Update the Switchgear / Breaker Model 06/14/2023 08:17 AM Actions
6372 CIM Joint Issues CIM Issues New High Inconsistencies in Nameplate data for DERs 06/12/2023 08:18 AM Actions
6368 WG14 Part 9 Issues CIM Issues New High

61968-9

The interplay between events and status measurements should be supported more cleanly 06/01/2023 11:03 AM Actions
6329 WG13 Issues CIM Issues New High

IEC61970-301, IEC61970-456

VsConverter required and optional attributes in SSH and SV Profiles 05/10/2023 11:18 AM Actions
6328 WG13 Issues CIM Issues New High

IEC 61970-301, IEC 61970-452, IEC 61070-600

Required usage of BusbarSection 02/07/2024 10:41 AM Actions
(151-200/2163) Per page: 25, 50, 100