485 IEC 61850 User Feedback Task Force Support 41 IOP_2013 Closed Normal Some switches discard the IEEE 802.1Q tag known as VLAN 0 on packets sent/received on the trunk ports. Others discard the packet 06/21/2022 09:00 AM Actions
484 IEC 61850 User Feedback Task Force Support 40 IOP_2013 Closed Normal A question was raised in regards can Report EntryIDs be reused after IED restart. If so, guidance needs to be given for system d 06/21/2022 09:00 AM Actions
483 IEC 61850 User Feedback Task Force Support 39 IOP_2013 Closed Normal A question was raised in regards to the expected behavior of a server/BRCB that has been purged (e.g. no events buffered) and th 06/21/2022 09:00 AM Actions
482 IEC 61850 User Feedback Task Force Support 38 IOP_2013 Closed Normal When should buffering start for a reserved and fully configured BRCB. The discussion was that buffering should probably begin up 06/21/2022 09:00 AM Actions
481 IEC 61850 User Feedback Task Force Support 37 IOP_2013 Closed Normal A question was raised in regards to how a client should resynchronize to receive the last report (Buffered Reporting). The sta 06/21/2022 09:00 AM Actions
480 IEC 61850 User Feedback Task Force Support 36 IOP_2013 Closed Normal A different client made use of a URCB that had been reserved in SCL for use by a different client via ClientLN. Currently, there 06/21/2022 09:00 AM Actions
479 IEC 61850 User Feedback Task Force Support 35 IOP_2013 Closed Normal An SCL file was produced that had a GOOSE DataSet that contained members that had FC=CO and FC=CF. The SCT performing the import 06/21/2022 09:00 AM Actions
478 IEC 61850 User Feedback Task Force Support 34 IOP_2013 Closed Normal There is currently no mechanism to allow an array member to be added as a DataSet member In the conformance tables of 8-1, alter 06/21/2022 09:00 AM Actions
477 IEC 61850 User Feedback Task Force Support 33 IOP_2013 Closed Normal Throughout the IOP, there was discussion about validation. However, validation has several different levels to it. There is no v 06/21/2022 09:00 AM Actions
476 IEC 61850 User Feedback Task Force Support 32 IOP_2013 Closed Normal Currently, in SCL, the size of an array is numeric. This could lead to issues of consistency (e.g. one having 32 array elements 06/21/2022 09:00 AM Actions
475 IEC 61850 User Feedback Task Force Support 31 IOP_2013 Closed Normal With the renaming of LNTypes, DOTypes, etc., there should be a specification as to the maximum size for these names. The XSD sho 06/21/2022 09:00 AM Actions
474 IEC 61850 User Feedback Task Force Support 30 IOP_2013 Closed Normal Should all SCTs support a substation section and the ability to associate LNodes into that section. 06/21/2022 09:00 AM Actions
473 IEC 61850 User Feedback Task Force Support 29 IOP_2013 Closed Normal An SCL file was provided that had a <Val> for an OctetString value. A question was raised as to the correct format for the value 06/21/2022 09:00 AM Actions
472 IEC 61850 User Feedback Task Force Support 28 IOP_2013 Closed Normal An ED.2 SCT would not import an ED.1 SCL file. This needs to be addressed with rules of transformation and the definition of a s 06/21/2022 09:00 AM Actions
471 IEC 61850 User Feedback Task Force Support 27 IOP_2013 Closed Normal How should an SCL file express the initial value of GOCB.Ena and SVCB.Ena. It would appear that the Control Block schema definit 06/21/2022 09:00 AM Actions
470 IEC 61850 User Feedback Task Force Support 26 IOP_2013 Closed Normal An ICT provides an IID/ICD file that defines 4 GOCBs. The SCT imports this file, creates an SCD which has only 1 GOCB. The ICT r 06/21/2022 09:00 AM Actions
469 IEC 61850 User Feedback Task Force Support 25 IOP_2013 Closed Normal The iedType attribute is optional within SCL. However, some SCL tools use this as part of validation. Lack of the attribute/valu 06/21/2022 09:00 AM Actions
468 IEC 61850 User Feedback Task Force Support 24 IOP_2013 Closed Normal The mechanism for defining a GI attribute in a ED.2 RCB does not validate and import into an ED.1 ICT. 06/21/2022 09:00 AM Actions
467 IEC 61850 User Feedback Task Force Support 23 IOP_2013 Closed Normal There are normative ENUM definitions for 7-4. (e.g. Mod) but there is no guidance in regards to naming rules (e.g. Modkind). 06/21/2022 09:00 AM Actions
466 IEC 61850 User Feedback Task Force Support 22 (2) IOP_2013 Closed Normal In a SCD there were LNodes in the substation section that were not associated to a specific IED/LN instance. The question was if 06/21/2022 09:00 AM Actions
465 IEC 61850 User Feedback Task Force Support 22 (1) IOP_2013 Closed Normal In a SCD there were LNodes in the substation section that were not associated to a specific IED/LN instance. In particular, an S 06/21/2022 09:00 AM Actions
464 IEC 61850 User Feedback Task Force Support 21 IOP_2013 Closed Normal There is an issue about differentiation between “fixed” /preconfigured DataSets and those that can be changed in a SCT. Some ICT 06/21/2022 09:00 AM Actions
462 IEC 61850 User Feedback Task Force Support 19 IOP_2013 Closed Normal The use of ExtRef to subscribe to a SV was questioned. There are several different mechanisms that could be used in 61850-6 to s 06/21/2022 09:00 AM Actions
460 IEC 61850 User Feedback Task Force Support 17 IOP_2013 Closed Normal The usage of ClientLN in RptEna is optional. What does this mean. 61850-6 made this option for backward compatibility with ED.1. 06/21/2022 09:00 AM Actions
456 IEC 61850 User Feedback Task Force Support 13 IOP_2013 Closed Normal A client only ICD did not have a ClientServices section. An SCT imported the file and assigned used the IED to reserve a RCB wit 06/21/2022 09:00 AM Actions
518 IEC 61850 User Feedback Task Force Support 34 IOP_2015 Closed Normal Does the SVID character have to be specifically mentioned to be within 10-34 characters? Some of the vendors have implemented th 06/21/2022 09:12 AM Actions
517 IEC 61850 User Feedback Task Force Support 33 IOP_2015 Closed Normal IEC 61850-9-3 slaves can by design lock themselves to IEEE C37.238 (Power Profile) masters. This is intended behavior, since IEC 06/21/2022 09:12 AM Actions
516 IEC 61850 User Feedback Task Force Support 32 IOP_2015 Closed Normal Buffered reporting testing – anomaly with resynch (write of entryId failed, but buffered reports still sent). Because of indexe 06/21/2022 09:12 AM Actions
515 IEC 61850 User Feedback Task Force Support 31 IOP_2015 Closed Normal These test cases assume that a server will send a negative response to an operate to the same value. Some servers will accept th 06/21/2022 09:12 AM Actions
514 IEC 61850 User Feedback Task Force Support 29 IOP_2015 Closed Normal Priority of error checking in controls – i.e. position-reached instead of Blocked-by-switching-hierarchy. The order of checks i 06/21/2022 09:12 AM Actions
507 IEC 61850 User Feedback Task Force Support 22 IOP_2015 Closed Normal If the client reads a SCD file and loads then the data model (or vice versa ???) what data shall a client compare? confRef’s, da 06/21/2022 09:10 AM Actions
520 IEC 61850 User Feedback Task Force Support 1 IOP_2017/1 Closed Normal IEC 61850-6 leaves the definition of the meaning of the authentication options to the SCSM. However, neither 8-1 nor IEC 62351-6 06/21/2022 09:13 AM Actions
527 IEC 61850 User Feedback Task Force Support 8 IOP_2017/10 Closed Normal Regarding the Network infrastructure: Some MU/SAMU cannot configure their SV stream to different VLAN ID , fixed to 0 (but can c 06/21/2022 09:13 AM Actions
533 IEC 61850 User Feedback Task Force Support 14 IOP_2017/23 Closed Normal MSVID shall be unique. The integrated application SCD file allowed duplicate SVID’s for two merging units. 06/21/2022 09:13 AM Actions
536 IEC 61850 User Feedback Task Force Support 17 IOP_2017/26 Closed Normal SCT did not import GOOSE and 3 of the sampled value control blocks that existed in PMU ICD file. This caused validation failures 06/21/2022 09:13 AM Actions
440 IEC 61850 User Feedback Task Force Support 3 Vattenfall Closed Normal The specified sigal has a utility process name independent of used protcol. E.g. "start of distance protection". Also link to a 06/21/2022 09:19 AM Actions
6756 General Testing Issues Improvement Closed Normal Should UCA accredit and Certify IEC 61850-3 04/16/2024 08:50 AM Actions
5921 General Testing Issues Improvement Resolved Normal Start using Vendor and Lab Submission Information 09/06/2022 09:33 AM Actions
3098 IEC 61850 User Feedback Task Force Improvement 1 WG17 In Progress Normal Need to Change 8-1 to allow multiple DOs to be written 03/29/2022 09:36 AM Actions
6674 Server Issues Closed Normal Discuss changes to submission form and Certificates 03/01/2024 10:10 AM Actions
6483 Server Issues Resolved Normal Need to be able to test 61850-7-420 09/05/2023 08:14 AM Actions
5910 Server Issues Closed Normal Need to test that IEDs support 1 Step and 2 Step clocks: IOP 2022 03/01/2024 09:53 AM Actions
5153 Server Issues Closed Normal Backward Compatibility of 61869-9 with 9-2 LE 01/25/2022 08:52 AM Actions
5095 Server Issues Closed Normal sAssN1 is missing detailed test case 06/02/2022 02:49 PM Actions
5094 Server Issues Closed Normal sFt2ab does not verify that the LastModified value is consistent or changes when file is modified 11/16/2021 08:58 AM Actions
678 Server Issues Closed Normal MirrorBlockCommand state not used for LNs without direct process interface (sCtl28) 09/14/2021 06:44 AM Actions
649 Server Issues Closed Normal Should vendors be required to provide a vendor specific NSD instead of MICS 08/24/2021 12:05 PM Actions
648 Server Issues Closed Normal Is MICS to be deprecated 03/23/2021 09:23 AM Actions
646 Client Issues Closed Normal test issue for watch 08/09/2021 08:10 PM Actions
642 Server Issues Closed Normal Blocked/Test-blocked does not impact CSWI->XCBR interface - Tissue Ready to Be Tested 09/14/2021 06:48 AM Actions
641 Server Issues Closed Normal Integrity will be buffered - Tissue Ready for Test Development 03/02/2021 08:52 AM Actions
616 Server Issues Closed Normal sCnf10 in Ed2 remove voltagelevel and bay name TEMPLATE 06/14/2022 08:28 AM Actions
6784 IEC 61850 Certificate IEC 61850 Certificate Approved Normal iRTU 05/03/2024 04:14 PM Actions
6783 IEC 61850 Certificate IEC 61850 Certificate Approved Normal CCI Power Plant Controller 05/03/2024 03:02 PM Actions
6782 IEC 61850 Certificate IEC 61850 Certificate Approved Normal iCE-CPU 05/03/2024 02:51 PM Actions
6781 IEC 61850 Certificate IEC 61850 Certificate Approved Normal EcoStruxure™ Power Automation System Engineering 05/03/2024 02:34 PM Actions
6772 IEC 61850 Certificate IEC 61850 Certificate Approved Normal EcoStruxure Foxboro SCADA SCD6000 CPU 04/28/2024 08:38 AM Actions
6771 IEC 61850 Certificate IEC 61850 Certificate Approved Normal EcoStruxure Foxboro SCADA SCD6000 CPU 04/30/2024 08:28 AM Actions
6770 IEC 61850 Certificate IEC 61850 Certificate Approved Normal EdgeHub DataWorX 04/24/2024 02:00 PM Actions
6763 IEC 61850 Certificate IEC 61850 Certificate Approved Normal ETOPD1000 04/15/2024 07:33 AM Actions
6762 IEC 61850 Certificate IEC 61850 Certificate Approved Normal YH-HSA-ICD 04/25/2024 07:23 AM Actions
6761 IEC 61850 Certificate IEC 61850 Certificate Approved Normal YH-HSA-ICD 04/25/2024 07:22 AM Actions
6760 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SEL-751 and SEL-787L (Variant) 04/15/2024 06:52 AM Actions
6759 IEC 61850 Certificate IEC 61850 Certificate Approved Normal PCM600 04/15/2024 06:45 AM Actions
6755 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Multilin N60 04/07/2024 11:11 AM Actions
6754 IEC 61850 Certificate IEC 61850 Certificate Approved Normal N60 04/30/2024 08:37 AM Actions
6748 IEC 61850 Certificate IEC 61850 Certificate Approved Normal IED1-E11D1 03/29/2024 09:16 AM Actions
6747 IEC 61850 Certificate IEC 61850 Certificate Approved Normal WAGO 750-8212/0040-0001 03/29/2024 09:06 AM Actions
6746 IEC 61850 Certificate IEC 61850 Certificate Approved Normal DW61850CLIENT 03/29/2024 09:07 AM Actions
6742 IEC 61850 Certificate IEC 61850 Certificate Approved Normal V321 Arc Flash Protection System 03/24/2024 02:16 PM Actions
6741 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SA-G3000 03/24/2024 02:10 PM Actions
6740 IEC 61850 Certificate IEC 61850 Certificate Approved Normal ALARM ANNUNCIATOR MBAS 0600 03/24/2024 01:50 PM Actions
6733 IEC 61850 Certificate IEC 61850 Certificate Approved Normal ETLID1000 03/11/2024 08:38 AM Actions
6732 IEC 61850 Certificate IEC 61850 Certificate Approved Normal ETMDU1000 03/11/2024 08:39 AM Actions
6731 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Micom P40 Agile 5th Generation P84 03/11/2024 08:24 AM Actions
6721 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SPiN-MDAS 02/24/2024 11:09 AM Actions
6720 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SPiN-CNAS 02/24/2024 11:10 AM Actions
6719 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SPiN-CNAS 02/24/2024 11:11 AM Actions
6718 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SPiN-CMAS 02/24/2024 10:52 AM Actions
6717 IEC 61850 Certificate IEC 61850 Certificate Approved Normal PowerLogic™ P5F30 protection relays 02/24/2024 10:42 AM Actions
6716 IEC 61850 Certificate IEC 61850 Certificate Approved Normal ETR600-T 02/24/2024 10:35 AM Actions
6715 IEC 61850 Certificate IEC 61850 Certificate Approved Normal ETR600-BC 02/24/2024 10:29 AM Actions
6709 IEC 61850 Certificate IEC 61850 Certificate Approved Normal DRTS 66L 02/13/2024 10:10 AM Actions
6708 IEC 61850 Certificate IEC 61850 Certificate Approved Normal DRTS 66L 02/13/2024 10:09 AM Actions
6707 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SLP-K140 02/11/2024 10:55 AM Actions
6706 IEC 61850 Certificate IEC 61850 Certificate Approved Normal STP-K120 02/10/2024 11:35 AM Actions
6705 IEC 61850 Certificate IEC 61850 Certificate Approved Normal VIPAMj3500II-TR 02/10/2024 10:43 AM Actions
6704 IEC 61850 Certificate IEC 61850 Certificate Approved Normal VIPAM3500plusFM 02/10/2024 10:38 AM Actions
6696 IEC 61850 Certificate IEC 61850 Certificate Approved Normal REX610 02/05/2024 07:49 AM Actions
6695 IEC 61850 Certificate IEC 61850 Certificate Approved Normal PCS-221S Merging Unit 02/05/2024 06:50 AM Actions
6694 IEC 61850 Certificate IEC 61850 Certificate Approved Normal PCS-902S Line Distance Relay 02/05/2024 08:53 AM Actions
6692 IEC 61850 Certificate IEC 61850 Certificate Approved Normal PowerLogic™ P3 02/03/2024 11:00 AM Actions
6691 IEC 61850 Certificate IEC 61850 Certificate Approved Normal PowerLogic™ P3U30 02/03/2024 10:55 AM Actions
6690 IEC 61850 Certificate IEC 61850 Certificate Approved Normal PCS-9710S Remote Terminal Unit 02/03/2024 10:49 AM Actions
6689 IEC 61850 Certificate IEC 61850 Certificate Approved Normal PowerLogicTM P3 02/03/2024 10:19 AM Actions
6683 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Prometer 540 01/21/2024 11:03 AM Actions
6682 IEC 61850 Certificate IEC 61850 Certificate Approved Normal NS3560 01/22/2024 07:08 AM Actions
6681 IEC 61850 Certificate IEC 61850 Certificate Approved Normal NSR-385AG 01/21/2024 10:50 AM Actions
6676 IEC 61850 Certificate IEC 61850 Certificate Approved Normal P841 (GE MiCOM Agile P841) 01/13/2024 08:37 AM Actions
6675 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Prometer 100 01/13/2024 08:27 AM Actions