Project

General

Profile

Issues

Filters

Apply Clear

# Project Tracker ID Source Status Priority Standard(s) Subject Updated
6368 WG14 Part 9 Issues CIM Issues New High

61968-9

The interplay between events and status measurements should be supported more cleanly 06/01/2023 11:03 AM Actions
6367 WG14 Part 9 Issues CIM Issues New Normal

61968-9

Prepay Metering 06/01/2023 08:51 AM Actions
6366 WG14 Part 9 Issues CIM Issues New Normal

61968-9

Ground as a phase 08/17/2023 10:29 AM Actions
6358 IEC TC57 WG10 Future Work WG10 Future Work New Normal

IEC 61850

IEC 61850-7-4 list of abbreviations 10/26/2023 04:56 AM Actions
6322 WG14 Part 9 Issues CIM Issues New Normal

61968-9

New "Low Loss Potential" Quality Code needed in Part 9 06/01/2023 08:37 AM Actions
6321 CIM Issues CIM Issues New Normal Update the description of MktActivityRecord 04/20/2023 03:46 AM Actions
6319 IEC TC57 WG10 Future Work WG10 Future Work New Normal

IEC 61850-6

maxAttributes - conflicting requirements between GOOSE and reporting 10/26/2023 04:58 AM Actions
6316 IEC TC57 WG10 Future Work WG10 Future Work RTE New Normal

IEC 61850-6

Clarification of using of ValKind, ValImport. 10/26/2023 04:58 AM Actions
6298 WG14 Part 9 Issues CIM Issues New Normal

61968-9

New Event codes needed in Part 9 for overvoltage and undervoltage 03/22/2023 08:48 AM Actions
6297 WG14 Part 9 Issues CIM Issues New Normal

61968-9

New Event code needed in Part 9 for DC Voltage 04/20/2023 09:54 AM Actions
6296 WG14 Part 9 Issues CIM Issues New Normal

61968-9

New "Transformer Compensated" Quality Code needed in Part 9 06/01/2023 08:10 AM Actions
6295 WG14 Issues CIM Issues New Normal

61968-9

Publication of meter firmware versions from Part 9 to Part 4. 03/21/2023 03:54 PM Actions
6294 WG14 Issues CIM Issues New Normal

61968-9

IRM 03/21/2023 03:46 PM Actions
6267 CIM Joint Issues CIM Issues New High

IEC61968-11

Person and Organization Relationships 02/15/2023 09:31 AM Actions
6266 CIM Issues CIM Issues New Normal

IEC61968-11

Person and Person Role Modeling 02/15/2023 09:21 AM Actions
6265 IEC TC57 WG10 Future Work WG10 Future Work New Normal

IEC 61850-6

track changes in SCL to know when a device needs to be updated based on new SCD version 02/19/2024 10:56 AM Actions
6249 CIM Issues CIM Issues New Normal Update CIM namespace 02/06/2023 01:17 PM Actions
6245 WG14 Part 3 Issues CIM Issues New Normal It is not possible to convey that an UnplannedOutage is frozen (prediction is suspended). 02/01/2023 02:29 PM Actions
6244 WG14 Part 3 Issues CIM Issues New Normal Part 3 should specify that you can use 'updated' verb 01/31/2023 03:32 PM Actions
6243 WG14 Part 3 Issues CIM Issues New Normal UnplannedOutages is missing OutageArea and AreaKind 01/31/2023 03:29 PM Actions
6242 WG14 Part 3 Issues CIM Issues New Normal OutageArea has nowhere to put the name of the outage area 01/31/2023 03:26 PM Actions
6241 WG14 Part 3 Issues CIM Issues New Normal UnplannedOutages does not provide a way to capture affected kVA for IEEE load-based indices 01/31/2023 03:23 PM Actions
6240 WG14 Part 3 Issues CIM Issues New Normal UnplannedOutages has no way to indicate that the outage should be excluded from reliability reporting. 01/31/2023 02:59 PM Actions
6239 WG14 Part 3 Issues CIM Issues New Normal UnplannedOutages profile needs ability to capture de-energized and energized times per UsagePoint 01/31/2023 02:26 PM Actions
6220 IEC TC57 WG10 Future Work WG10 Future Work New Normal

IEC 61850-7-4

Parameters not available in standardized GAPC LN - opDITmms, DITmms 10/26/2023 05:00 AM Actions
6194 WG14 Part 3 Issues CIM Issues New Normal PlannedOutageNotifications needs to support energize/de-energize time/date per UsagePoint. 11/29/2022 12:50 PM Actions
6185 IEC TC57 WG10 Future Work WG10 Future Work 2022 IOP New Normal

IEC 61850-6

SCL Need to differentiate the difference in the number of GOOSE vs R-GOOSE 10/26/2023 05:01 AM Actions
6165 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

TR IEC 61850-7-500

https://iec61850.tissue-db.com/tissue/1844 - Implementation of SumSwARs in 3-phase circuit breaker inaccurate 10/26/2023 05:01 AM Actions
6164 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

IEC 61850-7-4

https://iec61850.tissue-db.com/tissue/1825 - Permission mode for control/setting of a scheduled entity from a client 10/26/2023 05:03 AM Actions
6163 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

TR IEC 61850-7-5

https://iec61850.tissue-db.com/tissue/1804 - When e.g. LocSta = false, result of command to switch DO Mod with "station-control" not clear. 10/26/2023 05:06 AM Actions
6162 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

TR IEC 61850-7-500

https://iec61850.tissue-db.com/tissue/1803 - Mechanical Blocking of 3 way switches 10/26/2023 05:07 AM Actions
6161 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

TR IEC 61850-7-5

https://iec61850.tissue-db.com/tissue/1797 - SwModKey dependency of CSWI from LLN0 10/26/2023 05:08 AM Actions
6160 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

TR IEC 61850-90-29

https://iec61850.tissue-db.com/tissue/1796 LPHD.PwrSupAlm as Omulti 10/26/2023 05:13 AM Actions
6159 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

TR IEC 61850-90-3

https://iec61850.tissue-db.com/tissue/1789 SCBR - Coilxxx-Data-Objects shall be Omulti 10/26/2023 05:14 AM Actions
6158 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

IEC 61850-7-4

https://iec61850.tissue-db.com/tissue/1760 - OMulti for MMET data objects 10/26/2023 05:14 AM Actions
6156 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

IEC 61850-7-3

https://iec61850.tissue-db.com/tissue/1748 Arrays of CDC 10/26/2023 05:15 AM Actions
6155 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

TR IEC 61850-7-500

https://iec61850.tissue-db.com/tissue/1706 Missing LN for Miniature Circuit Breaker (MCB) 10/26/2023 05:19 AM Actions
6154 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

IEC 61850-7-4

https://iec61850.tissue-db.com/tissue/1698 AnOut in GAPC 10/26/2023 05:19 AM Actions
6153 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

IEC 61850-7-4

https://iec61850.tissue-db.com/tissue/1691 Contradictory statement for Mod.stVal 10/26/2023 05:19 AM Actions
6151 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

IEC 61850-7-3

Use and configuration of ORG within the scope of InRef 7 BlkRef 10/26/2023 05:20 AM Actions
6144 IEC TC57 WG10 Future Work WG10 Future Work IOP 2022 New Normal

IEC 61850-6

Need to add SCL mechanism to define a minimum MinTime 10/26/2023 05:21 AM Actions
6143 IEC TC57 WG10 Future Work WG10 Future Work New High

TR IEC 61850-7-500, TR IEC 61850-90-3

Update the Switchgear / Breaker Model 10/26/2023 03:50 AM Actions
5979 WG14 Part 9 Issues CIM Issues New Normal

IEC 61968-9 and others

Meter to UsagePoint relationship should be many-to-many 06/15/2023 09:32 AM Actions
5966 IEC TC57 WG10 Future Work WG10 Future Work EDF New Normal Indicate typical SIUnit for every DO with CDC MV would help users + Add a dedicated attribute in NSD files instead of having it in the description ? 04/08/2025 10:44 AM Actions
5965 IEC TC57 WG10 Future Work WG10 Future Work New Normal

IEC 61850-7-4

Schedules - allow updates to single values while schedules are running 02/08/2024 05:31 AM Actions
5964 IEC TC57 WG10 Future Work WG10 Future Work Tissue DB New Normal

IEC 61850-7-2

Incorrect Attribute type of TrgOp 02/08/2024 04:24 AM Actions
5950 WG14 Part 9 Issues CIM Issues New Normal

61968-9, 61968-11

How is readCycle used, should the definition be updated? 05/31/2023 07:13 PM Actions
5944 IEC TC57 WG10 Future Work WG10 Future Work RTE New Normal

IEC 61850-7-4

Need to create a new LN of group P (Protection), as "PCDP" to represent the Pole Discrepancy Protection. 02/08/2024 04:27 AM Actions
5943 IEC TC57 WG10 Future Work WG10 Future Work RTE New Normal

IEC 61850-7-4

New LN of group L (as "LTED") to represent the dynamic topology of the substation. 02/08/2024 04:35 AM Actions
5942 IEC TC57 WG10 Future Work WG10 Future Work RTE New Normal

IEC 61850-7-4

Activation and deactivation of a function by configuration. 02/08/2024 04:37 AM Actions
(151-200/2306) Per page: 25, 50, 100