CIM Issues #6366

Ground as a phase

Added by David Haynes over 1 year ago. Updated over 1 year ago.

Status:
New
Priority:
Normal
Author/Contact Info:
dhaynes@hubbell.com
Base Release:
Solution to be Applied To:
Solution Version:
Solution Applied By:
Completion Date:
08/18/2023
CIM Keywords:
Breaking Change:
Breaking Change Description:
CIM Impacted Groups:
WG14
Requestor:
David Haynes
Standard(s):

61968-9

Version:
4
Clause:
Annex C
Sub-Clause:
C.2.16
Paragraph:
1
Table:
C.17
Originally Closed in Version:
Origination Date:
06/01/2023
Origination ID:
Originally Assigned To:

Description

The ReadingTypeID field contains phases A,B,C, and N, but not ground. Sometimes the distinction between neutral and ground is important, and a GFCI's role is to measure the difference between the two.


Proposed Solution

Designate bits 15 and 16 to indicate ground ("G1" and "G2").
(When listed in a certain direction NG is distinguished from GN as the first one taking on a '1' and the second one a '2'.)


Decision

Discussed and accepted in the Part 9 team meeting on 8/17/23.

#1

Updated by David Haynes over 1 year ago

  • Proposed Solution updated (diff)
#2

Updated by David Haynes over 1 year ago

  • Completion Date set to 08/18/2023
  • Decision updated (diff)

Also available in: Atom PDF