General

Profile

David Haynes

  • Login: david.haynes
  • Registered on: 02/09/2022
  • Last connection: 06/12/2024

Issues

open closed Total
Assigned issues 0 0 0
Reported issues 25 0 25

Projects

Project Roles Registered on
WG14 Part 1 Issues Developer, Reporter 03/21/2023
WG14 Part 100 Issues Developer, Reporter 03/21/2023
WG14 Part 11 Issues Developer, Reporter 03/21/2023
WG14 Part 2 Issues Developer, Reporter 03/21/2023
WG14 Part 3 Issues Developer, Reporter 03/21/2023
WG14 Part 4 Issues Developer, Reporter 03/21/2023
WG14 Part 5 Issues Developer, Reporter 03/21/2023
WG14 Part 6 Issues Developer, Reporter 03/21/2023
WG14 Part 7 Issues Developer, Reporter 03/21/2023
WG14 Part 8 Issues Developer, Reporter 03/21/2023
WG14 Part 9 Issues Developer, Reporter 03/21/2023

Activity

06/12/2024

06:42 PM WG14 Part 5 Issues CIM Issues #6752: Deprecate Part 5 Modelling
WG14, especially Part 9, would like to preserve the notion of "groups". While Part 9 has always supported group names... David Haynes

03/07/2024

11:10 AM CIM Joint Issues CIM Issues #6729: Multi-commodity Support
Please see Redmine Issue #6730 David Haynes
10:57 AM CIM Joint Issues CIM Issues #6729 (New): Multi-commodity Support
Many utilities sell multiple commodities (electricity, gas, water, and more). Many vendors make products that support... David Haynes
11:09 AM CIM Joint Issues CIM Issues #6730 (New): Evaluation of the Pipeline Open Data Standard (PODS)
An organization that has a "pipes model" has been located. All of the WGs interested in Redmine issue #6729 should co... David Haynes

11/27/2023

12:29 PM WG14 Part 9 Issues CIM Issues #6611 (New): Formulaic UOMs
There is at least one utility in North America requiring the revenue meter to measure VA in a special way. If the PF ... David Haynes

11/16/2023

11:33 AM WG14 Part 9 Issues CIM Issues #6600 (New): Multipliers
There has been ambiguity in the world over the use of "k" and "M" as scalars. According to the official SI UOM standa... David Haynes

10/24/2023

06:22 PM WG14 Part 9 Issues CIM Issues #6549: Switch Contention Issue
David Haynes wrote:
> There are many relays controlling many loads. Sometimes these assets can be switched on or off...
David Haynes
05:26 PM WG14 Part 9 Issues CIM Issues #6549 (New): Switch Contention Issue
There are many relays controlling many loads. Sometimes these assets can be switched on or off for different reasons.... David Haynes
05:09 PM WG14 Part 9 Issues CIM Issues #6369: Support EVSE by adding new ReadingTypeID and EndDeviceEvent codes
In WG14 Meeting #81, Medina MN, Tom Berry suggests that we might want to look at what the DLMS/COSEM folks are doing ... David Haynes

10/19/2023

11:23 AM WG14 Part 9 Issues CIM Issues #6544 (New): Meter Asset Accuracy Class
Revenue meters have an attribute called "Accuracy Class". The Accuracy Class (AC) is commonly printed on the meter na... David Haynes

Also available in: Atom