# Project Tracker ID Source Status Priority Standard(s) Subject Updated
5216 WG14 Part 4 Issues CIM Issues Review Low Add kindOther to Asset 07/03/2023 09:48 AM Actions
5218 WG14 Part 4 Issues CIM Issues Review Low Deprecate AssetOrganisationRole 07/03/2023 09:25 AM Actions
4848 WG13 Issues CIM Issues Closed Low SCADA calculations 06/21/2023 10:16 AM Actions
4891 WG13 Issues CIM Issues Closed Low Mapping of a number to a name. "Name" is not a good name 06/21/2023 10:14 AM Actions
4802 WG13 Issues CIM Issues Review Low Alternate modelsIssue from Jim Waight about EMS model and 06/15/2023 05:04 AM Actions
4944 WG13 Issues CIM Issues Closed Low Combining bus-branch and breaker-nodemodels is unclear. Th 02/07/2023 01:57 PM Actions
4938 WG13 Issues CIM Issues Closed Low qPccControl missing for CSCTwo possibilities should be ava 02/07/2023 01:36 PM Actions
4931 WG13 Issues CIM Issues Closed Low Specification of equipment for network analysisIt is commo 02/07/2023 01:25 PM Actions
4930 WG13 Issues CIM Issues Closed Low ENTSO-E 13 - EquivalentInjection support WardEquivalentInj 02/07/2023 01:22 PM Actions
4929 WG13 Issues CIM Issues Closed Low ENTSO-E 12 - SynchronousMachine PU Some attributes need to 02/07/2023 01:19 PM Actions
4928 WG13 Issues CIM Issues Closed Low ENTSO-E 9 TapChanger ltcFlag confusingThe note "The attrib 02/07/2023 01:12 PM Actions
4927 WG13 Issues CIM Issues Closed Low ENTSO-E 4 - MAS in SV headerThe MAS indicated in the SV pr 02/07/2023 12:12 PM Actions
4925 WG13 Issues CIM Issues Closed Low SynchronousMachine.type should use full type nameThe attri 02/07/2023 12:05 PM Actions
4924 WG13 Issues CIM Issues Closed Low StaticVarCompensator sign confusion of reactianceThere is 02/07/2023 11:58 AM Actions
4921 WG13 Issues CIM Issues Closed Low MeasurementType for normative table for phase voltages We 02/07/2023 11:51 AM Actions
4894 WG13 Issues CIM Issues Closed Low ETXSiemens - DayType - This matches Siemens model. Needs c 02/07/2023 11:26 AM Actions
5812 WG16 Issues CIM Issues Open Low Add a new BusinessSector class in the MarketManagement package. 09/22/2022 11:41 AM Actions
5813 WG16 Issues CIM Issues Open Low Add attribute type (string) in the BusinessSector class to tell the specific Businss sector [required]. 09/22/2022 11:41 AM Actions
5814 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the MarketDocument class (many-many-association). 09/22/2022 11:41 AM Actions
5815 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the TimeSeries class (many-many-association). 09/22/2022 11:40 AM Actions
5816 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the MktActivityRecord class (many-many-association). 09/22/2022 11:40 AM Actions
5062 WG13 Issues CIM Issues Open Low DC auxiliary equipment support 05/09/2022 10:37 AM Actions
4946 WG13 Issues CIM Issues Open Low HydroPowerPlant inherit PSR There is Plant class that inher 09/14/2021 03:47 PM Actions
4940 WG13 Issues CIM Issues Open Low Outage model for HVDC Which HVDC equipment need to be descr 09/14/2021 03:47 PM Actions
3990 WG13 Issues CIM Issues Closed Low Clean up jCleanCim errors. There are many attributes with 09/14/2021 03:43 PM Actions
3986 WG13 Issues CIM Issues Closed Low xmlns:cim Currently the name space is changed with every CI 09/14/2021 03:43 PM Actions
3922 WG13 Issues CIM Issues Closed Low Angle measurements Direct angle SCADA measurements need to 09/14/2021 03:43 PM Actions
524 IEC 61850 User Feedback Task Force Support 5 IOP_2017/7 Closed Normal

1-Aug

The use of the Simulation bit in the R-GOOSE Payload is not clearly defined. It refers only to 8-1 which currently only specifie 06/21/2022 09:13 AM Actions
511 IEC 61850 User Feedback Task Force Support 26 IOP_2015 Closed Normal

2-Sep

The Quality bits alignment in 9-2LE seems different from 8-1 quality bits with ASN.1. So it caused confusion that which bit shou 06/21/2022 09:12 AM Actions
424 IEC 61850 User Feedback Task Force Support 15 ENTSO-E Closed Normal

6

Vendor Tools shall allow (vendor independant) Integration tools doing engineering based on ICD Files, thus allowing them to in 12/06/2022 09:01 AM Actions
535 IEC 61850 User Feedback Task Force Support 16 IOP_2017/25 Closed Normal

6

SCD file removed unconfigured GOOSE control block but did not remove the Connected AP section contained GSE information. 06/21/2022 09:13 AM Actions
506 IEC 61850 User Feedback Task Force Support 21 IOP_2015 Closed Normal

6

Issue 1: Content of CID with GOOSE Subscriptions During testing we noticed some CID files contained a single IED, whereas others 06/21/2022 09:12 AM Actions
505 IEC 61850 User Feedback Task Force Support 20 IOP_2015 Closed Normal

6

Statement: an SCT A export an SED file with engineering rights “fix” and expectation was SCT B could add Goose clients after imp 06/21/2022 09:12 AM Actions
504 IEC 61850 User Feedback Task Force Support 19 IOP_2015 Closed Normal

6

When IID file from ICT includes “mustUnderstand” attribute in <GSEcontrol> such as <GSEControl desc="System Logical Device GOOS 06/21/2022 09:12 AM Actions
503 IEC 61850 User Feedback Task Force Support 18 IOP_2015 Closed Normal

6

Issue 1: History section is present in ICD but during import SCT is discarding this history section. Also, maintenance of histor 06/21/2022 09:12 AM Actions
502 IEC 61850 User Feedback Task Force Support 17 IOP_2015 Closed Normal

6

Issue 1: During import of SSD file SST/SCT is not able to recognize Busbar connection node. It is connectivity node and there i 06/21/2022 09:12 AM Actions
501 IEC 61850 User Feedback Task Force Support 16 IOP_2015 Closed Normal

6

PAUL MYRDA: In SCL it is possible to define unbuffered report control blocks with indexed set to false but with max instances se 06/21/2022 09:12 AM Actions
500 IEC 61850 User Feedback Task Force Support 15 IOP_2015 Closed Normal

6

2.2. BufMod is optional for ReportControl. No default value provided by the schema. SCT is interpreting as unbuffered only. Com 06/21/2022 09:12 AM Actions
499 IEC 61850 User Feedback Task Force Support 14 IOP_2015 Closed Normal

6

Issue 4 – Private section – namespace moved from SCL node to Private nodes ICT added the namespace within the privates instead o 06/21/2022 09:12 AM Actions
498 IEC 61850 User Feedback Task Force Support 13 IOP_2015 Closed Normal

6

Issue 3 – GoCB confRev - behaviour if ConfRev=“0“ IED rejected that value. 7-2: If there are inconsistent attribute values in t 06/21/2022 09:12 AM Actions
497 IEC 61850 User Feedback Task Force Support 12 IOP_2015 Closed Normal

6

Issue 2 - IED restrictions not known by SCT 2.1 IED support 50% URCB and 50% BRCB Service section provide a total RCB number 2. 06/21/2022 09:12 AM Actions
496 IEC 61850 User Feedback Task Force Support 11 IOP_2015 Closed Normal

6

DUSTIN: Issue 3: Symmetrical Bindings of DA In case of late Binding at DO/DA Level. IED expects DO at later binding, but source 06/21/2022 09:12 AM Actions
495 IEC 61850 User Feedback Task Force Support 10 IOP_2015 Closed Normal

6

Issue 2: SCT Behavior When Revising/Replacing IED Configuration Between SCT Tools In terms of the data model structure and comm 06/21/2022 09:12 AM Actions
494 IEC 61850 User Feedback Task Force Support 9 IOP_2015 Closed Normal

6

DUSTIN: Issue 1: X/Y Coordinates Upon exchanging the SCD file between SCT tools, the drawing/visualization of the single line d 06/21/2022 09:12 AM Actions
493 IEC 61850 User Feedback Task Force Support 8 IOP_2015 Closed Normal

6

An icd/iid file is not required to include the “original SCL” element. Is it required to be added to the IED instance in the SCD 06/21/2022 09:12 AM Actions
492 IEC 61850 User Feedback Task Force Support 7 IOP_2015 Closed Normal

6

(a) If a device does not support configuration of the ctlModel for a specific DO – what is the correct way to declare this? • De 06/21/2022 09:12 AM Actions
491 IEC 61850 User Feedback Task Force Support 6 IOP_2015 Closed Normal

6

Declaration of CtlModel for controllable CDCs (a) If a device does not support configuration of the ctlModel for a specific DO – 06/21/2022 09:11 AM Actions
490 IEC 61850 User Feedback Task Force Support 5 IOP_2015 Closed Normal

6

In the service section, an IED can declare “modify dataset” to be FALSE. That means, datasets in the IED cannot be changed by th 06/21/2022 09:11 AM Actions
489 IEC 61850 User Feedback Task Force Support 4 IOP_2015 Closed Normal

6

Declaration of Clients in an SCL file: The icd/iid file of a client only device can have a LN at the level of the access point. 06/21/2022 09:11 AM Actions
488 IEC 61850 User Feedback Task Force Support 3 IOP_2015 Closed Normal

6

An ICD file has predefined ReportControlBlock. With the SCT we attached a dataset to one URCB. Afterwards we decide to de-config 06/21/2022 09:11 AM Actions