5316 CIM Joint Issues CIM Issues Open Normal

IEC 61968 series

How to best associate the CIM with other related information standards such as ERP, GML, and BIM 02/13/2023 12:23 PM Actions
3923 CIM Joint Issues CIM Issues Open Normal

61970-301, 61970-452, 61970-600

Inconsistent use of LineCurrent, Current, PhaseCurrent meas 06/28/2023 09:31 AM Actions
5963 CIM Joint Issues CIM Issues Review High mRID topics [incl GMDM #19] 12/11/2023 11:27 AM Actions
6454 CIM Issues CIM Issues New Normal

61970-301

RemoteUnit minor typo in 301 description 06/28/2023 04:27 PM Actions
6321 CIM Issues CIM Issues New Normal Update the description of MktActivityRecord 04/20/2023 03:46 AM Actions
6266 CIM Issues CIM Issues New Normal

IEC61968-11

Person and Person Role Modeling 02/15/2023 09:21 AM Actions
6249 CIM Issues CIM Issues New Normal Update CIM namespace 02/06/2023 01:17 PM Actions
5885 CIM Issues CIM Issues New Normal

IEC 61970-301

Consider CIM measurement classes that can hold multiple measured values with the same timestamp and quality. 07/13/2022 10:50 AM Actions
5884 CIM Issues CIM Issues New Normal Modify control model - create DiscreteCommand for enumerations such as raise/lower 07/13/2022 10:45 AM Actions
5883 CIM Issues CIM Issues New Normal

IEC 61970-301

Define a standard way to define IEC 61850 data object names for MeasurementTypes and ControlTypes 07/13/2022 10:31 AM Actions
5882 CIM Issues CIM Issues New Normal

IEC 61970-301

Model fans, motors, battery systems and similar auxiliary equipment with terminals 07/13/2022 10:24 AM Actions
6768 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Control of substituted or blocked objects 04/19/2024 05:08 AM Actions
6699 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Behavior of a function while being dynamically blocked 02/07/2024 04:55 AM Actions
6698 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Integrate work from AHTF Control Between Functions 02/07/2024 02:29 AM Actions
6686 61850-7-5 and 61850-7-500 IEC61850-7-5 Tissue #1892 New Normal Description of the different control methods to change position of OLTC (in automatic, manual modes) 01/23/2024 11:02 AM Actions
6684 61850-7-5 and 61850-7-500 IEC61850-7-5 discussion New Normal Proposal to deprecate 'LocSta' in X and Y group LN classes 01/22/2024 02:50 AM Actions
6607 61850-7-5 and 61850-7-500 IEC61850-7-5 RTE New Normal Create DO indicating the source of synchronisation 11/21/2023 08:49 AM Actions
6606 61850-7-5 and 61850-7-500 IEC61850-7-5 RTE New Normal CPU monitoring 11/21/2023 08:40 AM Actions
6562 61850-7-5 and 61850-7-500 IEC61850-7-5 Redmine: 6155 New Normal Missing LN for Miniature Circuit Breaker (MCB) 10/26/2023 05:17 AM Actions
6560 61850-7-5 and 61850-7-500 IEC61850-7-5 Redmine: 6443 New Normal Multiple information sources 10/26/2023 04:02 AM Actions
6559 61850-7-5 and 61850-7-500 IEC61850-7-5 Redmine: 6443 New Normal Modelling of a Lockout/trip seal-in relay 04/19/2024 09:19 AM Actions
6558 61850-7-5 and 61850-7-500 IEC61850-7-5 Redmine: 6443 New Normal How to model composed functions 10/26/2023 04:01 AM Actions
6557 61850-7-5 and 61850-7-500 IEC61850-7-5 Redmine: 6443 New Normal Modelling of various MCB trips 10/26/2023 04:00 AM Actions
6556 61850-7-5 and 61850-7-500 IEC61850-7-5 Redmine: 6443 New Normal How to impact the data quality of a data with respect to the communication links, the intermediate processing, the device hosting it. 10/26/2023 04:00 AM Actions
6555 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Behaviour of output contacts when LN is in blocked mode 02/07/2024 03:14 AM Actions
6537 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Harmonizing expressions in 7-500 Ed.1 10/06/2023 08:13 AM Actions
6497 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Explanation text of IEC/TR 61850-7-500 clause 10.1.1.2 08/02/2023 10:43 AM Actions
6496 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Typo in section 13.3 08/02/2023 08:54 AM Actions
6408 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification of addCause 06/20/2023 08:37 AM Actions
6407 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - allow 3 values per time point 06/20/2023 08:36 AM Actions
6406 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - add optional data objects to support irregular interval schedules 06/20/2023 08:36 AM Actions
6405 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - allow updates to single values while schedules are running 06/20/2023 08:35 AM Actions
6387 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal S/S related applications: Auxiliary circuit supervision 06/14/2023 08:20 AM Actions
6386 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Voltage protection: Overvoltage protection - 3ph operate 06/14/2023 08:20 AM Actions
6385 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Voltage protection: Undervoltage protection - 3ph operate 06/14/2023 08:19 AM Actions
6384 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal New controllable DO in RREC to define the mode of the recloser of the circuit breaker 06/14/2023 08:19 AM Actions
6383 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Single phase and multi phase trip indication for the autorecloser 06/14/2023 08:19 AM Actions
6382 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 1/3 06/14/2023 08:18 AM Actions
6380 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 2/3 06/14/2023 08:18 AM Actions
6379 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 3/3 06/14/2023 08:17 AM Actions
6377 61850-7-5 and 61850-7-500 IEC61850-7-5 New High Update the Switchgear / Breaker Model 06/14/2023 08:17 AM Actions
6376 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal LN PDIF – setting for nominal current 02/13/2024 05:59 AM Actions
6726 61850-7-5 and 61850-7-500 IEC61850-7-5 RTE In Progress Normal New LN of group L (as "LTED") to represent the dynamic topology of the substation. 02/29/2024 09:07 AM Actions
6725 61850-7-5 and 61850-7-500 IEC61850-7-5 RTE In Progress Normal Simultaneous change of InRef.setSrcRef and InRef.setSrcCB for dynamic commutation 02/29/2024 09:07 AM Actions
6711 61850-7-5 and 61850-7-500 IEC61850-7-5 WG10 Fall workshop In Progress Low SCL Modelling of Fault Measurements (RFMX) 02/29/2024 08:33 AM Actions
6500 61850-7-5 and 61850-7-500 IEC61850-7-5 In Progress Normal Parameters to enforce the checking of interlocking and synchronism 10/05/2023 08:57 AM Actions
6499 61850-7-5 and 61850-7-500 IEC61850-7-5 In Progress Normal Explanation text on the application of check conditions 10/05/2023 08:57 AM Actions
6482 61850-7-5 and 61850-7-500 IEC61850-7-5 In Progress Normal Figures 36, 37, 38 09/14/2023 07:56 AM Actions
6394 61850-7-5 and 61850-7-500 IEC61850-7-5 In Progress Normal Clarifications on the local/remote concept 8/8 09/14/2023 08:04 AM Actions
6393 61850-7-5 and 61850-7-500 IEC61850-7-5 In Progress Normal Clarifications on the local/remote concept 7/8 10/05/2023 08:55 AM Actions