Project

General

Profile

Issues

Filters

Apply Clear

# Project Tracker ID Source Status Priority Standard(s) Subject Updated
6735 WG16 Issues CIM Issues New Normal new disclaimer note on every Inf* UML diagram indicating to “use at your own risk” 03/11/2024 02:54 PM Actions
5762 WG16 Issues CIM Issues Open Normal RegisteredLoad clean-up of attributes 08/08/2022 05:20 PM Actions
5839 WG16 Issues CIM Issues Open Normal ResourceCapacity; Propose to use DecimalQuantity for the attributes defaultCapacity, maximumCapacity, minimumCapacity 08/08/2022 05:56 PM Actions
6766 WG16 Issues CIM Issues In Progress Normal ResourceCertification attribute type is generic and could be renamed to a more describe attribute name 04/18/2024 10:37 AM Actions
6764 WG16 Issues CIM Issues In Progress Normal ResourceCertification.qualificationFlag description is incorrect 04/18/2024 10:40 AM Actions
6765 WG16 Issues CIM Issues In Progress Normal ResourceCertification.type - update the description to describe the usage of the attribute "type" 04/18/2024 10:25 AM Actions
6734 WG16 Issues CIM Issues New Normal Review use/inheritance of Document by UCA TF 16 classes, profile, standards 03/11/2024 09:58 AM Actions
5750 WG16 Issues CIM Issues Open Normal The characteristics of a MSG Generating Plant uses similar definition as a RegisteredGenerator. 07/19/2022 05:59 PM Actions
5863 WG16 Issues CIM Issues Open Normal Update the set of DemandSideResourceInterfaceProfiles from WG21 08/08/2022 06:05 PM Actions
5970 IEC 61850 User Feedback Task Force Improvement 2022 f2F IOP In Progress Normal

IEC 61850-6

SCT behavior needs to be specified regarding mismatch between substation section and IED section 11/08/2022 08:24 AM Actions
6175 IEC 61850 User Feedback Task Force Bug 2022 IOP In Progress Normal

IEC 61850-6

SCL SICS requires SNTP even with 2.1 where PTP is the preferred method. 11/07/2023 08:21 AM Actions
6185 IEC TC57 WG10 Future Work WG10 Future Work 2022 IOP New Normal

IEC 61850-6

SCL Need to differentiate the difference in the number of GOOSE vs R-GOOSE 10/26/2023 05:01 AM Actions
6684 61850-7-5 and 61850-7-500 IEC61850-7-5 discussion New Normal Proposal to deprecate 'LocSta' in X and Y group LN classes 01/22/2024 02:50 AM Actions
5335 IEC 61850 User Feedback Task Force Improvement Dustin Tessier Resolved Normal

IEC 61850-90-4

Adding Normative Requirements & Conformance Testing Pertaining to Broadcast Storms 06/05/2023 01:58 AM Actions
6703 IEC TC57 WG10 Future Work WG10 Future Work Ed 3 review New Normal

IEC 61850-7-4, IEC TS 61850-80-4

Part 80-4 Mapping to COSEM : add reactive and apparent energy data objects to MMTR and MMTN 02/09/2024 02:43 PM Actions
5955 IEC 61850 User Feedback Task Force Improvement EDF Resolved Normal Indicate typical SIUnit for every DO with CDC MV would help users + Add a dedicated attribute in NSD files instead of having it in the description ? 06/05/2023 01:58 AM Actions
6248 IEC 61850 User Feedback Task Force Improvement EDF Resolved Normal

IEC 61850-6

There are controls between IEDs for automatic control functions, we need to be able to represent those controls in SCL (for configuration in SCT, data flow documentation...) 06/14/2023 08:33 AM Actions
5966 IEC TC57 WG10 Future Work WG10 Future Work EDF New Normal Indicate typical SIUnit for every DO with CDC MV would help users + Add a dedicated attribute in NSD files instead of having it in the description ? 02/09/2024 04:02 AM Actions
6167 IEC 61850 User Feedback Task Force Support email Resolved Normal

IEC 61850-90-6

IEC 61850-90-6 Voltage presence CDC for SVPI.Prs 06/05/2023 01:58 AM Actions
572 IEC 61850 User Feedback Task Force Support 44 ENTSO-E Resolved Normal

IEC 61850-7-500

S/S related applications: Auxiliary circuit supervision 05/09/2023 09:32 AM Actions
647 IEC 61850 User Feedback Task Force Support 57 ENTSO-E Resolved Normal

IEC 61850-7-500

Single phase and multi phase trip indication for the autorecloser 05/09/2023 09:32 AM Actions
579 IEC 61850 User Feedback Task Force Support 51 ENTSO-E Resolved Normal

IEC 61850-7-500

Voltage protection: Overvoltage protection - 3ph operate 05/09/2023 09:32 AM Actions
580 IEC 61850 User Feedback Task Force Support 52 ENTSO-E Resolved Normal

IEC 61850-7-500

Voltage protection: Undervoltage protection - 3ph operate 05/09/2023 09:32 AM Actions
5876 IEC 61850 User Feedback Task Force Improvement FNN Germany Resolved Normal

IEC 61850-7-4 Ed.3

Proposal of a new LN class ASWI 06/05/2023 01:58 AM Actions
5933 IEC TC57 WG10 Future Work WG10 Future Work FNN Germany New Normal

IEC 61850-7-4

Proposal of a new LN class ASWI 02/08/2024 05:06 AM Actions
(1976-2000/2163) Per page: 25, 50, 100