Project

General

Profile

Issues

Filters

Apply Clear

# Project Tracker ID Source Status Priority Standard(s) Subject Updated
1878 IEC 61850 Certificate IEC 61850 Certificate Approved Normal CCU 1000 Central Control Unit [GE Digital Energy] 07/08/2021 04:13 PM Actions
1877 IEC 61850 Certificate IEC 61850 Certificate Approved Normal STCE/RTU [Selta S.p.A] 07/08/2021 04:13 PM Actions
1876 IEC 61850 Certificate IEC 61850 Certificate Approved Normal IDS ACOS750 [IDS GmbH] 07/08/2021 04:13 PM Actions
1875 IEC 61850 Certificate IEC 61850 Certificate Approved Normal wPD [WOODAM TECH CO., LTD.] 07/08/2021 04:13 PM Actions
1874 IEC 61850 Certificate IEC 61850 Certificate Approved Normal DW-SPIN [Daewoong Electric Co. Ltd.] 07/10/2021 08:19 PM Actions
1873 IEC 61850 Certificate IEC 61850 Certificate Approved Normal EuroGateway [Protecta Electronics Co. Ltd.] 07/08/2021 04:13 PM Actions
1872 IEC 61850 Certificate IEC 61850 Certificate Approved Normal COPA-DATA IEC850 [Ing. Punzenberger COPA-DATA GmbH] 07/08/2021 04:13 PM Actions
1871 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SCD5200 [Invensys Operations Management] 07/08/2021 04:13 PM Actions
1870 IEC 61850 Certificate IEC 61850 Certificate Approved Normal TOPAS-SA [LSIS Co., Ltd.] 07/08/2021 04:13 PM Actions
1869 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SAMCAS [U2S Co., Ltd] 07/08/2021 04:13 PM Actions
1868 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Telvent subCAT [Telvent Energia, S.A.] 07/09/2021 09:16 AM Actions
1867 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Siemens SICAM PAS [Siemens AG ] 07/08/2021 04:13 PM Actions
1866 IEC 61850 Certificate IEC 61850 Certificate Approved Normal CP-MUP [ABB Switzerland Ltd.] 06/13/2022 03:24 PM Actions
724 Gateway Certificates OpenFMB Gateway Approved Normal OES Gateway 08/20/2021 01:13 PM Actions
602 IEC 61850 User Feedback Task Force Feature 1742 IOP_2019 Resolved Normal

IEC 61850-9-3

Merging Unit standard requires MU clock to jump on PTP time jumps, which is not true for Boundary Clocks. 05/09/2023 09:32 AM Actions
599 IEC 61850 User Feedback Task Force Feature 12 IOP_2019 Resolved Normal ICD files do not match requirements (several issues) - increase in engineering efforts 06/05/2023 01:58 AM Actions
597 IEC 61850 User Feedback Task Force Feature 1120 IOP_2019 Resolved Normal

61850-90-28

SCTs updating the confRev of 9-2 LE Sampled Value streams - problem with subscription to test tool SV injection 05/09/2023 09:32 AM Actions
590 IEC 61850 User Feedback Task Force Feature 1800 IOP_2019 Resolved Normal

IEC 61850-6

ICT fails to check validity of the SCD file regarding the IED constraints 11/07/2023 08:22 AM Actions
580 IEC 61850 User Feedback Task Force Support 52 ENTSO-E Resolved Normal

IEC 61850-7-500

Voltage protection: Undervoltage protection - 3ph operate 05/09/2023 09:32 AM Actions
579 IEC 61850 User Feedback Task Force Support 51 ENTSO-E Resolved Normal

IEC 61850-7-500

Voltage protection: Overvoltage protection - 3ph operate 05/09/2023 09:32 AM Actions
572 IEC 61850 User Feedback Task Force Support 44 ENTSO-E Resolved Normal

IEC 61850-7-500

S/S related applications: Auxiliary circuit supervision 05/09/2023 09:32 AM Actions
556 IEC 61850 User Feedback Task Force Support 3 H30 In Progress Normal

IEC 61850-90-20

Rendundant CT/TT measurements 06/21/2022 02:09 AM Actions
555 IEC 61850 User Feedback Task Force Support 2 H30 Rejected Normal Link Failover reliability problem - implication to protection application 10/25/2022 09:01 AM Actions
554 IEC 61850 User Feedback Task Force Support 1 H30 Resolved Normal Performance requirement for SV and implications to Protection applications 05/09/2023 09:32 AM Actions
553 IEC 61850 User Feedback Task Force Support 34 IOP_2017/55 Resolved Normal

IEC 61850-9-3

IEC/IEEE 61850-9-3 should clarify the meaning and use of TimeTraceable and FrequencyTraceable 05/09/2023 09:32 AM Actions
(1601-1625/1635) Per page: 25, 50, 100

Also available in: Atom CSV PDF