# Project Tracker ID Source Status Priority Standard(s) Subject Updated
535 IEC 61850 User Feedback Task Force Support 16 IOP_2017/25 Closed Normal

6

SCD file removed unconfigured GOOSE control block but did not remove the Connected AP section contained GSE information. 06/21/2022 09:13 AM Actions
528 IEC 61850 User Feedback Task Force Feature 9 IOP_2017/15 Closed Normal

IEC 61850-6

SCD files have type defined where bType does not equal Enum or Struct, which does not follow the IEC 61850-6 description 06/21/2022 09:24 AM Actions
414 IEC 61850 User Feedback Task Force Support 6.2 ENTSO-E Closed Normal SCD from system integrator not containing comprehensive substation section 02/03/2021 02:42 PM Actions
2216 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SCD5200 [Invensys Operations Management] 07/08/2021 04:29 PM Actions
1884 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SCD5200 [Invensys Operations Management] 07/08/2021 04:13 PM Actions
1871 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SCD5200 [Invensys Operations Management] 07/08/2021 04:13 PM Actions
6176 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Schneider Easergy MiCOM P545 Edition 2 Server 11/08/2022 08:39 AM Actions
2391 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Schneider MiCOM P532 [Schneider Electric] 07/09/2021 09:31 AM Actions
2412 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Schneider MiCOM P645 [Schneider Electric Infrastructure Business China] 07/09/2021 09:31 AM Actions
2392 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Schneider MiCOM P841 [Schneider Electric] 07/09/2021 09:31 AM Actions
2393 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Schneider MiCOM P849 [Schneider Electric Infrastructure Business China] 07/09/2021 09:31 AM Actions
2427 IEC 61850 Certificate IEC 61850 Certificate Approved Normal Schneider Sepam M87 [Schneider Electric] 07/09/2021 09:31 AM Actions
6185 IEC TC57 WG10 Future Work WG10 Future Work 2022 IOP New Normal

IEC 61850-6

SCL Need to differentiate the difference in the number of GOOSE vs R-GOOSE 10/26/2023 05:01 AM Actions
6175 IEC 61850 User Feedback Task Force Bug 2022 IOP In Progress Normal

IEC 61850-6

SCL SICS requires SNTP even with 2.1 where PTP is the preferred method. 11/07/2023 08:21 AM Actions
584 IEC 61850 User Feedback Task Force Feature 1122 IOP_2019 Closed Normal

IEC 61850-6

SCL validation - Should all name parts of PhV be contained in the doName? 05/09/2023 09:12 AM Actions
437 IEC 61850 User Feedback Task Force Support 28 ENTSO-E Closed Normal

IEC 61850-6

SCL: Use of InRef and ExtRef not possible in many tools 02/11/2021 06:57 AM Actions
616 Server Issues Closed Normal sCnf10 in Ed2 remove voltagelevel and bay name TEMPLATE 06/14/2022 08:28 AM Actions
2830 IEC 61850 Certificate IEC 61850 Certificate Approved Normal SCOPE advanced Automation Mgmt System [SCOPE T&M Pvt. Ltd.] 07/11/2021 10:12 AM Actions
426 IEC 61850 User Feedback Task Force Support 17 ENTSO-E Closed Normal

IEC 61850-6

SCT and ICD Service section handling 02/11/2021 07:43 AM Actions
5970 IEC 61850 User Feedback Task Force Improvement 2022 f2F IOP In Progress Normal

IEC 61850-6

SCT behavior needs to be specified regarding mismatch between substation section and IED section 11/08/2022 08:24 AM Actions
536 IEC 61850 User Feedback Task Force Support 17 IOP_2017/26 Closed Normal SCT did not import GOOSE and 3 of the sampled value control blocks that existed in PMU ICD file. This caused validation failures 06/21/2022 09:13 AM Actions
538 IEC 61850 User Feedback Task Force Support 19 IOP_2017/29 Closed Normal

IEC 61850-6

SCT engineering problems 06/21/2022 09:24 AM Actions
529 IEC 61850 User Feedback Task Force Feature 10 IOP_2017/16 Closed Normal

IEC 61850-6

SCT imports ICD with SGCB, and the settings with FC= SP outside this setting group are changed to FC=SE in the exported DOType part 06/21/2022 09:24 AM Actions
530 IEC 61850 User Feedback Task Force Feature 11 IOP_2017/20 Closed Normal

IEC 61850-6

SCT is passing ICD errors to SCD. 06/21/2022 09:24 AM Actions
585 IEC 61850 User Feedback Task Force Feature 1337 IOP_2019 Closed Normal

IEC 61850-6

SCT unable to configure the device to communicate on multiple subnets due to having a single AP (with all Eth. Ports) 07/05/2022 08:24 AM Actions