Project

General

Profile

Issues

Filters

Apply Clear

# Project Tracker ID Source Status Priority Standard(s) Subject Updated
4793 WG13 Issues CIM Issues Closed Normal Transformer status duplication Duplication between PowerTra 09/14/2021 03:47 PM Actions
4862 WG13 Issues CIM Issues Closed Normal Transformer regulation There is a need for modification of 09/14/2021 03:47 PM Actions
4861 WG13 Issues CIM Issues Closed Normal Transformer Switch from "Y" to "Delta" type of modelling. T 09/14/2021 03:47 PM Actions
4017 WG13 Issues CIM Issues Closed Normal Topoogy package dependencies overstated The dependency of M 09/14/2021 03:43 PM Actions
4137 WG13 Issues CIM Issues Closed Normal TopologicalNode injections The TN injections pinjection and 09/14/2021 03:44 PM Actions
4394 WG13 Issues CIM Issues Closed Normal To indicate the value of the active and reactive power gene 09/14/2021 03:45 PM Actions
4396 WG13 Issues CIM Issues Closed Normal To compare Load Flow results, we need to have agreement on 09/14/2021 03:45 PM Actions
4243 WG13 Issues CIM Issues Closed Normal To allow the all substation containers to keep their object 09/14/2021 03:44 PM Actions
5732 WG16 Issues CIM Issues Closed Normal TimeSeries new attribute to cancel 07/19/2022 05:46 PM Actions
5734 WG16 Issues CIM Issues Closed Normal TimeSeries new attribute for price 07/19/2022 05:46 PM Actions
5736 WG16 Issues CIM Issues Closed Normal TimeSeries and Point class new attributes for Quantity 07/19/2022 05:47 PM Actions
4352 WG13 Issues CIM Issues Closed Normal Time Series model is needed. 09/14/2021 03:45 PM Actions
4888 WG13 Issues CIM Issues Closed Normal TieFlow Direction The new class TieFlow does not clearly st 09/14/2021 03:47 PM Actions
4398 WG13 Issues CIM Issues Closed Normal Three winding transformers are modeled in the CIM, but they 09/14/2021 03:45 PM Actions
4766 WG13 Issues CIM Issues Closed Normal Three attributes of Quality have initial (default) value 'F 09/14/2021 03:46 PM Actions
4340 WG13 Issues CIM Issues Closed Normal This standard (IEC 61970-301) should be able to used in all 09/14/2021 03:45 PM Actions
4199 WG13 Issues CIM Issues Closed Normal This seection currently reads: It is the recursive relation 09/14/2021 03:44 PM Actions
4400 WG13 Issues CIM Issues Closed Normal This question is linked to the previous one. It may be usef 09/14/2021 03:45 PM Actions
4837 WG13 Issues CIM Issues Closed Normal This issue number 736 was skipped. It is assumed there was 09/14/2021 03:47 PM Actions
4473 WG13 Issues CIM Issues Closed Normal This is one of rare classes (out of Domain package), that d 09/14/2021 03:45 PM Actions
4820 WG13 Issues CIM Issues Closed Normal ThermalGeneratingUnit could possibly be a superclass to Nuc 09/14/2021 03:47 PM Actions
4364 WG13 Issues CIM Issues Closed Normal There should be a general rule, if possible, to explain sit 09/14/2021 03:45 PM Actions
4427 WG13 Issues CIM Issues Closed Normal There is currently an inconsistency in the rules followed f 09/14/2021 03:45 PM Actions
4465 WG13 Issues CIM Issues Closed Normal There is clear spec on how to relate this String attribute 09/14/2021 03:45 PM Actions
4269 WG13 Issues CIM Issues Closed Normal There is ambiguity in the CPSM profile: The CIM allows mult 09/14/2021 03:44 PM Actions
4336 WG13 Issues CIM Issues Closed Normal There is a spelling error - "Requlating Equipment" in the t 09/14/2021 03:45 PM Actions
4295 WG13 Issues CIM Issues Closed Normal There is a need for a sub-class of AC line segment that has 09/14/2021 03:44 PM Actions
4437 WG13 Issues CIM Issues Closed Normal There is a CIM class called "StationSupply" which represent 09/14/2021 03:45 PM Actions
3947 WG13 Issues CIM Issues Closed Normal There are some subtypes of Curve (formerly CurveSchedule) w 09/14/2021 03:43 PM Actions
4343 WG13 Issues CIM Issues Closed Normal There are not UseState attributes to show use state or non- 09/14/2021 03:45 PM Actions
4835 WG13 Issues CIM Issues Closed Normal There are no 'type' information in reverseDifferences and r 09/14/2021 03:47 PM Actions
4426 WG13 Issues CIM Issues Closed Normal There are at least three ways to get to a regulated measure 09/14/2021 03:45 PM Actions
4316 WG13 Issues CIM Issues Closed Normal There are aspects of Assets that are in Wires. 09/14/2021 03:45 PM Actions
4256 WG13 Issues CIM Issues Closed Normal The use of the EnergyConsumer attributes pfixedPct and pnom 09/14/2021 03:44 PM Actions
4257 WG13 Issues CIM Issues Closed Normal The use of EquivalentSource is unclear (it may be a remnant 09/14/2021 03:44 PM Actions
4409 WG13 Issues CIM Issues Closed Normal The unit for susceptances is Siemens in the CIM. In fact, 09/14/2021 03:45 PM Actions
4261 WG13 Issues CIM Issues Closed Normal The TransformerWinding.windingID attribute may be redundant 09/14/2021 03:44 PM Actions
4877 WG13 Issues CIM Issues Closed Normal The TopologicalNode.loadCarrying attribute is unclear. The 09/14/2021 03:47 PM Actions
4423 WG13 Issues CIM Issues Closed Normal The TopologicalNode is defined as "A set of connectivity no 09/14/2021 03:45 PM Actions
4248 WG13 Issues CIM Issues Closed Normal The SubstationEquipmentContainer shall be renamed to Equipm 09/14/2021 03:44 PM Actions
4259 WG13 Issues CIM Issues Closed Normal The StaticVarCompensator MVA rating is lacking. 09/14/2021 03:44 PM Actions
4258 WG13 Issues CIM Issues Closed Normal The StaticVarCompensator attribute slope is in PU while the 09/14/2021 03:44 PM Actions
4061 WG13 Issues CIM Issues Closed Normal The RotatingMachine.parametersFormType is undocumented. The 09/14/2021 03:43 PM Actions
4436 WG13 Issues CIM Issues Closed Normal The requirements of individual people, crews and work tasks 09/14/2021 03:45 PM Actions
4227 WG13 Issues CIM Issues Closed Normal The requirements for MeasurementValueSource is not clear. 09/14/2021 03:44 PM Actions
4283 WG13 Issues CIM Issues Closed Normal The relationship between SubControlArea and GeneratingUnit 09/14/2021 03:44 PM Actions
4392 WG13 Issues CIM Issues Closed Normal The question is about the number of TapChangers on a transf 09/14/2021 03:45 PM Actions
4255 WG13 Issues CIM Issues Closed Normal The purpose and use of the class Condenser is unclear. 09/14/2021 03:44 PM Actions
4247 WG13 Issues CIM Issues Closed Normal The PSR.typeName attribute actualle designates the type of 09/14/2021 03:44 PM Actions
4222 WG13 Issues CIM Issues Closed Normal The profiles need to be able to specify a format for exchan 09/14/2021 03:44 PM Actions
(201-250/1448) Per page: 25, 50, 100

Also available in: Atom CSV PDF