CIM Issues #4137
TopologicalNode injections The TN injections pinjection and
Status:
Closed
Priority:
Normal
Author/Contact Info:
WG13
Base Release:
61970cim16v22
Solution to be Applied To:
61970cim16v24
Solution Version:
CIM16
Solution Applied By:
LOO
Completion Date:
09/19/2013
CIM Keywords:
Breaking Change:
No
Breaking Change Description:
CIM Impacted Groups:
WG13
Requestor:
Standard(s):
Version:
Clause:
Sub-Clause:
Paragraph:
Table:
Originally Closed in Version:
CIM16
Origination Date:
06/24/2013
Origination ID:
13_177
Originally Assigned To:
Description
TopologicalNode injections
The TN injections pinjection and qinjection usage is questioned. It is suggested to replace these attributes with ConductingEquipment. Reason is that in boundaries it does not work to put the boundary mismatch in the pinjection and qinjection.
Proposed Solution
Remove TopologicalNode pinjection and qinjection.
The different use cases are not clear, e.g. SE put the mismatch in SvInjection or TopologicalNode and it way be used by a power flow to get the same start condition agreeing with the SE output. So question is how does this fit with SSH. This need to be further explored before decided.
2013-07-03/LOO
Decision
Documentation updated according minutes from 2013-09-18.