General

Profile

Pat Brown

  • Login: patricia.brown
  • Registered on: 10/03/2021
  • Last connection: 05/24/2023

Issues

open closed Total
Assigned issues 0 0 0
Reported issues 22 2 24

Projects

Project Roles Registered on
CIM Joint Issues Developer 10/03/2021
WG13 Issues Developer 10/03/2021
WG14 Issues Developer 10/03/2021
WG14 Part 1 Issues Developer 01/10/2022
WG14 Part 100 Issues Developer 01/10/2022
WG14 Part 11 Issues Developer 01/10/2022
WG14 Part 2 Issues Developer 01/10/2022
WG14 Part 3 Issues Developer 01/10/2022
WG14 Part 4 Issues Developer 01/10/2022
WG14 Part 5 Issues Developer 01/10/2022
WG14 Part 6 Issues Developer 01/10/2022
WG14 Part 7 Issues Developer 01/10/2022
WG14 Part 8 Issues Developer 01/10/2022
WG14 Part 9 Issues Developer 01/10/2022

Activity

05/24/2023

12:56 PM WG13 Issues CIM Issues #6357 (New): [GMDM #9] Modeling behind the inverter
The GMDM IOP model included a BatteryUnit, PhotovoltaicUnit, and WindPowerElectronicsUnit behind the same residential... Pat Brown
12:53 PM WG13 Issues CIM Issues #6356 (New): [GMDM #22] 61968-13 has SwitchPhase.closed attribute in Functional not SSH.
The .closed attribute on SwitchPhase should be in the Steady State Hypothesis profile (in the current 61968-13 it is ... Pat Brown
12:37 PM WG13 Issues CIM Issues #6355 (New): [GMDM #20] Clarification of extension association expression in rdfs
Associations are described by 2 resources (one representing each direction of the association). The general conventio... Pat Brown
12:07 PM WG13 Issues CIM Issues #6350 (New): [GMDM #18] Rationalise 61968-13 and 61970-4xx profiles
There are two sets of grid model data profiles - 61970-4xxx and 61968-13. They rely on the same underlying informatio... Pat Brown
11:13 AM WG13 Issues CIM Issues #6348 (New): [GMDM #16] correct capitalisation of PhotoVoltaicUnit class name
The word ‘photovoltaic’ is one word, so the class name PhotoVoltaicUnit should be PhotovoltaicUnit. Pat Brown
09:59 AM WG13 Issues CIM Issues #6347 (New): [GMDM #15] Add a limited amount of ‘structure’ modeling to distribution grid models
There are a few types of structures (poles primary among them) that are typically included in the grid modeling used ... Pat Brown
09:53 AM WG13 Issues CIM Issues #6346 (New): [GMDM #14] Indicating starting point for feeder tracing
The GMDM test model expressed the nominal containership of each ConductingEquipment child in a Feeder by means of the... Pat Brown
09:28 AM WG13 Issues CIM Issues #6345 (New): [GMDM #13] Overhead / underground indicator on equipment
An indication of whether distribution equipment is overhead or underground is very useful particularly in the operati... Pat Brown
09:23 AM WG13 Issues CIM Issues #6344 (New): [GMDM #10] Add .orderedPhases attribute on LinearShuntCompensatorPhase
Replace the LinearShuntCompensatorPhase.phase attribute with an .orderedPhases attribute. This allows more accurate m... Pat Brown
09:03 AM WG13 Issues CIM Issues #6343 (New): [GMDM #7] Convention for use of xxxPhase classes
The question is whether there should be an assumption that a ConductingEquipment is 3-phase if xxxPhase classes are n... Pat Brown

Also available in: Atom