4929 WG13 Issues CIM Issues Closed Low ENTSO-E 12 - SynchronousMachine PU Some attributes need to 02/07/2023 01:19 PM Actions
4928 WG13 Issues CIM Issues Closed Low ENTSO-E 9 TapChanger ltcFlag confusingThe note "The attrib 02/07/2023 01:12 PM Actions
4927 WG13 Issues CIM Issues Closed Low ENTSO-E 4 - MAS in SV headerThe MAS indicated in the SV pr 02/07/2023 12:12 PM Actions
4925 WG13 Issues CIM Issues Closed Low SynchronousMachine.type should use full type nameThe attri 02/07/2023 12:05 PM Actions
4924 WG13 Issues CIM Issues Closed Low StaticVarCompensator sign confusion of reactianceThere is 02/07/2023 11:58 AM Actions
4921 WG13 Issues CIM Issues Closed Low MeasurementType for normative table for phase voltages We 02/07/2023 11:51 AM Actions
4894 WG13 Issues CIM Issues Closed Low ETXSiemens - DayType - This matches Siemens model. Needs c 02/07/2023 11:26 AM Actions
5812 WG16 Issues CIM Issues Open Low Add a new BusinessSector class in the MarketManagement package. 09/22/2022 11:41 AM Actions
5813 WG16 Issues CIM Issues Open Low Add attribute type (string) in the BusinessSector class to tell the specific Businss sector [required]. 09/22/2022 11:41 AM Actions
5814 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the MarketDocument class (many-many-association). 09/22/2022 11:41 AM Actions
5815 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the TimeSeries class (many-many-association). 09/22/2022 11:40 AM Actions
5816 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the MktActivityRecord class (many-many-association). 09/22/2022 11:40 AM Actions
5062 WG13 Issues CIM Issues Open Low DC auxiliary equipment support 05/09/2022 10:37 AM Actions
4946 WG13 Issues CIM Issues Open Low HydroPowerPlant inherit PSR There is Plant class that inher 09/14/2021 03:47 PM Actions
4940 WG13 Issues CIM Issues Open Low Outage model for HVDC Which HVDC equipment need to be descr 09/14/2021 03:47 PM Actions
3990 WG13 Issues CIM Issues Closed Low Clean up jCleanCim errors. There are many attributes with 09/14/2021 03:43 PM Actions
3986 WG13 Issues CIM Issues Closed Low xmlns:cim Currently the name space is changed with every CI 09/14/2021 03:43 PM Actions
3922 WG13 Issues CIM Issues Closed Low Angle measurements Direct angle SCADA measurements need to 09/14/2021 03:43 PM Actions
5970 IEC 61850 User Feedback Task Force Improvement 2022 f2F IOP In Progress Normal

IEC 61850-6

SCT behavior needs to be specified regarding mismatch between substation section and IED section 11/08/2022 08:24 AM Actions
6175 IEC 61850 User Feedback Task Force Bug 2022 IOP In Progress Normal

IEC 61850-6

SCL SICS requires SNTP even with 2.1 where PTP is the preferred method. 11/07/2023 08:21 AM Actions
6185 IEC TC57 WG10 Future Work WG10 Future Work 2022 IOP New Normal

IEC 61850-6

SCL Need to differentiate the difference in the number of GOOSE vs R-GOOSE 10/26/2023 05:01 AM Actions
403 IEC 61850 User Feedback Task Force Bug 1 ENTSO-E Closed High Problem exchanging SCL file between tools 02/09/2021 06:22 AM Actions
408 IEC 61850 User Feedback Task Force Bug 3.2 ENTSO-E Closed High PICS, MICS and other statements documents are not formally defined 02/09/2021 06:20 AM Actions
410 IEC 61850 User Feedback Task Force Bug 4.2 ENTSO-E Closed High Data models using GGIO when not needed 02/09/2021 06:19 AM Actions
406 IEC 61850 User Feedback Task Force Bug 2.3 ENTSO-E Closed High Configuration of datasets by users 02/03/2021 03:55 PM Actions