Issues
open | closed | Total | |
---|---|---|---|
Assigned issues | 49 | 85 | 134 |
Reported issues | 45 | 53 | 98 |
Projects
Project | Roles | Registered on |
---|---|---|
Test Procedure Issues | IEC 61850 TPWG Entry, IEC61850_TPWG_MANAGER, IEC61850_TPWG_DEVELOPER, IEC61850_TPWG_REPORTER | 09/10/2021 |
Client | IEC61850_TPWG_MANAGER, IEC61850_TPWG_DEVELOPER, IEC61850_TPWG_REPORTER | 02/16/2021 |
GOOSE Performance | IEC61850_TPWG_MANAGER, IEC61850_TPWG_DEVELOPER, IEC61850_TPWG_REPORTER | 02/16/2021 |
SCL Tooling | IEC61850_TPWG_MANAGER, IEC61850_TPWG_DEVELOPER, IEC61850_TPWG_REPORTER | 02/16/2021 |
Server | Manager, IEC61850_TPWG_MANAGER, IEC61850_TPWG_DEVELOPER, IEC61850_TPWG_REPORTER | 02/16/2021 |
Activity
11/11/2024
- 09:53 AM Server Issues #6991: sCnf75 not all devices have control objects
- Solution (changes in bold):
Verify for each (instance of) DOType/DA[name=ctlModel] whose associated EnumType conta... - 09:48 AM Server Issues #6988: sCtl16 in TP1.3 is in conflict with 7-4 Table B.1
- Improved version attached.
10/30/2024
- 04:25 AM Server Issues #6897: sCnf7, sCnf66 services can be defined on IED and AccessPoint when identical
- Solution attached
10/29/2024
- 07:30 AM Server Issues #6886: Tissue 1897 Data-change and data-update inclusion bitstring bits set in a report
- sRp3/sBr3 already states in the expected result: "the reason code is *one* of the configured trigger options". This ...
10/18/2024
- 04:42 AM Server Issues #7028: There is no conformance procedure/block for TimeOperated Control
- TimeActivedOperate is a conditional service in block 12a, 12b, 12c and 12d. The corresponding test cases are: sDOns4,...
- 04:35 AM Client Issues #7029 (Resolved): cFtN3 step 2: SetFile has no Ed1 specific error code
- Same as for cSrvN10 and cLogN5 the SetFile has no Ed1 specific error code.
I propose to remove cFtN3 step 2 (step 1...
09/27/2024
- 03:40 AM Server Issues #6904 (In Progress): sCtl14 in TP1.3 does not reflect the Issue #6214 resolution
- Indeed sCtl14 need to be improved. PIXIT Ct30 is only about operate time and is not relevant for expected result step...
09/20/2024
- 07:04 AM Server Issues #6991 (Resolved): sCnf75 not all devices have control objects
- Change to conditional with condition:
Condition: when Operate is supported (PICS) - 06:55 AM Server Issues #6990 (In Progress): sSvp9 step 4 PTP class not 6/7 with/without holdover time?
- IEEE 1588 defines clock class 6-7-52-187. When the master clock looses the GPS signal the master will continue. After...
- 06:29 AM Server Issues #6989 (Resolved): sSvp14 for Backwards the max MSVID is 34 char not 32
- 9-2LE figure 4 shows SvID 10..34 chars. The maximum length is 34 chars! The test case states 32 chars as maximum leng...