654 Server Issues Rejected Low Publish/subscribe minimum length data GOOSE 01/24/2023 09:02 AM Actions
651 Server Issues Rejected Low Verify subscriber can accept maximum size GOOSE 01/24/2023 08:40 AM Actions
6178 WG13 Issues CIM Issues New Low Relation between ResourcePerformanceEvaluation and ResourcePerformanceGlobalFactor contains a typo at the source side (role) of the association. 11/11/2022 08:12 AM Actions
5812 WG16 Issues CIM Issues Open Low Add a new BusinessSector class in the MarketManagement package. 09/22/2022 11:41 AM Actions
5813 WG16 Issues CIM Issues Open Low Add attribute type (string) in the BusinessSector class to tell the specific Businss sector [required]. 09/22/2022 11:41 AM Actions
5814 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the MarketDocument class (many-many-association). 09/22/2022 11:41 AM Actions
5815 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the TimeSeries class (many-many-association). 09/22/2022 11:40 AM Actions
5816 WG16 Issues CIM Issues Open Low Associate the class BusinessSector with the MktActivityRecord class (many-many-association). 09/22/2022 11:40 AM Actions
5971 WG13 Issues CIM Issues New Low CIM-61850 Harmonization - Consider modelling fans, pump motors and battery systems as types of auxiliary equipment 09/21/2022 04:01 AM Actions
5973 WG13 Issues CIM Issues New Low CIM-61850 Harmonization - consider Measurement classes with multiple values (vector, Wye ...) 09/21/2022 03:36 AM Actions
5062 WG13 Issues CIM Issues Open Low DC auxiliary equipment support 05/09/2022 10:37 AM Actions
4946 WG13 Issues CIM Issues Open Low HydroPowerPlant inherit PSR There is Plant class that inher 09/14/2021 03:47 PM Actions
4940 WG13 Issues CIM Issues Open Low Outage model for HVDC Which HVDC equipment need to be descr 09/14/2021 03:47 PM Actions
5970 IEC 61850 User Feedback Task Force Improvement 2022 f2F IOP In Progress Normal

IEC 61850-6

SCT behavior needs to be specified regarding mismatch between substation section and IED section 11/08/2022 08:24 AM Actions
6175 IEC 61850 User Feedback Task Force Bug 2022 IOP In Progress Normal

IEC 61850-6

SCL SICS requires SNTP even with 2.1 where PTP is the preferred method. 11/07/2023 08:21 AM Actions
6185 IEC TC57 WG10 Future Work WG10 Future Work 2022 IOP New Normal

IEC 61850-6

SCL Need to differentiate the difference in the number of GOOSE vs R-GOOSE 10/26/2023 05:01 AM Actions
6684 61850-7-5 and 61850-7-500 IEC61850-7-5 discussion New Normal Proposal to deprecate 'LocSta' in X and Y group LN classes 01/22/2024 02:50 AM Actions
5335 IEC 61850 User Feedback Task Force Improvement Dustin Tessier Resolved Normal

IEC 61850-90-4

Adding Normative Requirements & Conformance Testing Pertaining to Broadcast Storms 06/05/2023 01:58 AM Actions
6703 IEC TC57 WG10 Future Work WG10 Future Work Ed 3 review New Normal

IEC 61850-7-4, IEC TS 61850-80-4

Part 80-4 Mapping to COSEM : add reactive and apparent energy data objects to MMTR and MMTN 02/09/2024 02:43 PM Actions
5966 IEC TC57 WG10 Future Work WG10 Future Work EDF New Normal Indicate typical SIUnit for every DO with CDC MV would help users + Add a dedicated attribute in NSD files instead of having it in the description ? 02/09/2024 04:02 AM Actions
6248 IEC 61850 User Feedback Task Force Improvement EDF Resolved Normal

IEC 61850-6

There are controls between IEDs for automatic control functions, we need to be able to represent those controls in SCL (for configuration in SCT, data flow documentation...) 06/14/2023 08:33 AM Actions
5955 IEC 61850 User Feedback Task Force Improvement EDF Resolved Normal Indicate typical SIUnit for every DO with CDC MV would help users + Add a dedicated attribute in NSD files instead of having it in the description ? 06/05/2023 01:58 AM Actions
6167 IEC 61850 User Feedback Task Force Support email Resolved Normal

IEC 61850-90-6

IEC 61850-90-6 Voltage presence CDC for SVPI.Prs 06/05/2023 01:58 AM Actions
647 IEC 61850 User Feedback Task Force Support 57 ENTSO-E Resolved Normal

IEC 61850-7-500

Single phase and multi phase trip indication for the autorecloser 05/09/2023 09:32 AM Actions
580 IEC 61850 User Feedback Task Force Support 52 ENTSO-E Resolved Normal

IEC 61850-7-500

Voltage protection: Undervoltage protection - 3ph operate 05/09/2023 09:32 AM Actions