Explicit association between TransformerTank and TransformerTankInfo
61968-11, 61968-4, 61970-301, 61968-13
Description
The existing AssetInfo.PowerSystemResource association allows associations between instances of child classes that are utterly illogical. This forces each profile using the AssetInfo.PowerSystemResource association to re-articulate constraints that are universal and would more logically be expressed in the canonical UML. This issue aims to start correcting the problem by suggesting one specific association.
Pat (2023-05-24): This could be condsidered as a part of issue 6147 - Streamlining of tank-based transformer modelling
Files
Decision
Need to coordinate between the 61968-4 for creating AssetInfoAssembly and current Transformer model to test procedure dataset.
This issue is related to GMDM issue #1 (Yang to add) (09/22/2022)
Release Notes
An association between TransformerTankInfo (source) and TransformerTank (target) has been added.