# Project Tracker ID Source Status Priority Standard(s) Subject Updated
6557 61850-7-5 and 61850-7-500 IEC61850-7-5 Redmine: 6443 New Normal Modelling of various MCB trips 10/26/2023 04:00 AM Actions
6556 61850-7-5 and 61850-7-500 IEC61850-7-5 Redmine: 6443 New Normal How to impact the data quality of a data with respect to the communication links, the intermediate processing, the device hosting it. 10/26/2023 04:00 AM Actions
6555 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Behaviour of output contacts when LN is in blocked mode 02/07/2024 03:14 AM Actions
6537 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Harmonizing expressions in 7-500 Ed.1 10/06/2023 08:13 AM Actions
6497 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Explanation text of IEC/TR 61850-7-500 clause 10.1.1.2 08/02/2023 10:43 AM Actions
6496 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Typo in section 13.3 08/02/2023 08:54 AM Actions
6408 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification of addCause 06/20/2023 08:37 AM Actions
6407 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - allow 3 values per time point 06/20/2023 08:36 AM Actions
6406 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - add optional data objects to support irregular interval schedules 06/20/2023 08:36 AM Actions
6405 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - allow updates to single values while schedules are running 06/20/2023 08:35 AM Actions
6387 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal S/S related applications: Auxiliary circuit supervision 06/14/2023 08:20 AM Actions
6386 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Voltage protection: Overvoltage protection - 3ph operate 06/14/2023 08:20 AM Actions
6385 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Voltage protection: Undervoltage protection - 3ph operate 06/14/2023 08:19 AM Actions
6384 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal New controllable DO in RREC to define the mode of the recloser of the circuit breaker 06/14/2023 08:19 AM Actions
6383 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Single phase and multi phase trip indication for the autorecloser 06/14/2023 08:19 AM Actions
6382 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 1/3 06/14/2023 08:18 AM Actions
6380 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 2/3 06/14/2023 08:18 AM Actions
6379 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 3/3 06/14/2023 08:17 AM Actions
6376 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal LN PDIF – setting for nominal current 02/13/2024 05:59 AM Actions
6454 CIM Issues CIM Issues New Normal

61970-301

RemoteUnit minor typo in 301 description 06/28/2023 04:27 PM Actions
6321 CIM Issues CIM Issues New Normal Update the description of MktActivityRecord 04/20/2023 03:46 AM Actions
6266 CIM Issues CIM Issues New Normal

IEC61968-11

Person and Person Role Modeling 02/15/2023 09:21 AM Actions
6249 CIM Issues CIM Issues New Normal Update CIM namespace 02/06/2023 01:17 PM Actions
5885 CIM Issues CIM Issues New Normal

IEC 61970-301

Consider CIM measurement classes that can hold multiple measured values with the same timestamp and quality. 07/13/2022 10:50 AM Actions
5884 CIM Issues CIM Issues New Normal Modify control model - create DiscreteCommand for enumerations such as raise/lower 07/13/2022 10:45 AM Actions
(76-100/2163) Per page: 25, 50, 100