Improvement #630

XCBR LN new DO to describe withdrawable circuit breaker

Added by Carlos Rodriguez del Castillo almost 4 years ago. Updated over 1 year ago.

Status:
Resolved
Priority:
Normal
Assignee:
-
Category:
Standard extension required
Start date:
12/17/2020
Due date:
06/17/2021 (over 3 years late)
% Done:

0%

Estimated time:
ID:
43
Source:
RTE
TF Unique ID:
43 # RTE
WG10 Proposal:
Estimated Completion:
Discuss in Upcoming Meeting:
No
To discuss in WG10:
No
Short Proposal:

Will be addressed by 7-5/7-500 Task Force.

Standard(s):

IEC 61850-7-500

Needs More Information:
No
Assigned TF:

Description

Need new DO in LN XCBR to describe withdrawable circuit breaker.
The informations needed are : position disconnected, DJ disconnected, DJ plugged in, Dryer fault.
A backup solution is to use LN XSWI. XSWI.Pos indicates whether the withdrawable circuit breaker is connected or deconnected.
Needed for some PACS functions.


Proposal descriptions

To be discussed inside WG10, as today it could be done with XCBR+XSWI, but it is not really a disconnector.


Related issues

Copied to 61850-7-5 and 61850-7-500 - IEC61850-7-5 #6375: XCBR LN new DO to describe withdrawable circuit breakerIn ProgressChristoph Brunner12/17/202006/17/2021

Actions
#1

Updated by Carlos Rodriguez del Castillo almost 4 years ago

  • Status changed from New to In Progress
  • Short Proposal set to To be discussed under WG10. To be discussed inside WG10.

It could be done today with XCBR+XSWI, but it is not really a disconnector.

#2

Updated by Carlos Rodriguez del Castillo almost 4 years ago

  • Status changed from In Progress to Triage
  • Short Proposal deleted (To be discussed under WG10. To be discussed inside WG10.)
  • Proposal descriptions updated (diff)
  • To discuss in WG10 set to Yes
#3

Updated by Carlos Rodriguez del Castillo over 3 years ago

  • Due date set to 06/17/2021
#4

Updated by Carlos Rodriguez del Castillo over 3 years ago

  • Discuss in Upcoming Meeting changed from Yes to No
#5

Updated by Carlos Rodriguez del Castillo almost 3 years ago

  • Status changed from Triage to Resolved
  • Short Proposal set to Will be addressed by 7-5/7-500 Task Force.
  • Standard(s) set to IEC 61850-7-5/7-500

- 7-5/7-500 meeting today addressed this topic and they decided to address there to make a proposal.
- If model extensions are needed, 7-5/7-500 will be need some extra inputs from other task forces.

#6

Updated by Carlos Rodriguez del Castillo almost 3 years ago

  • To discuss in WG10 changed from Yes to No
#7

Updated by Carlos Rodriguez del Castillo over 1 year ago

  • Standard(s) changed from IEC 61850-7-5/7-500 to IEC 61850-7-500
  • Needs More Information set to Yes
#8

Updated by Carlos Rodriguez del Castillo over 1 year ago

  • Needs More Information changed from Yes to No
#9

Updated by Vladan Cvejic over 1 year ago

  • Copied to IEC61850-7-5 #6375: XCBR LN new DO to describe withdrawable circuit breaker added

Also available in: Atom PDF