IEC 61850 User Feedback Task Force Reporter, MANAGER_UFTF 02/09/2021

Activity

12/06/2022

09:39 AM IEC 61850 User Feedback Task Force Feature #6186: Changing the ActSG while reservation by another client is ongoing
- Editing and Activating Setting groups are two independent actions
- UF TF suggest that there should be no change r...
Vladan Cvejic
09:38 AM IEC 61850 User Feedback Task Force Support #583 (Closed): Autoreclosure: Autoreclosure - 3ph closing command missing
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic
09:37 AM IEC 61850 User Feedback Task Force Support #582 (Closed): Synchrocheck: Synchrocheck - missing signals
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic
09:37 AM IEC 61850 User Feedback Task Force Support #581 (Closed): S/S related applications: Disturbance recorder - communication session active
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic
09:37 AM IEC 61850 User Feedback Task Force Feature #578 (Closed): Busbar protection: End Fault protection - model definition required.
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic
09:37 AM IEC 61850 User Feedback Task Force Feature #576 (Closed): Distance protection: Distance protection - 1 phase and 3 phase zone extension signals are missing
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic
09:36 AM IEC 61850 User Feedback Task Force Feature #575 (Closed): Protection scheme: Reversal current logic LN/DO/DA missing
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic
09:36 AM IEC 61850 User Feedback Task Force Feature #574 (Closed): Protection scheme: Weak end infeed (1 phase and 2/3 phase operate missing)
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic
09:36 AM IEC 61850 User Feedback Task Force Feature #573 (Closed): Tap Changer Supervision: Tap discrepancy (3 pole transformer case)
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic
09:36 AM IEC 61850 User Feedback Task Force Support #569 (Closed): S/S related applications: Access security system
Since there is no representation from ENTSO-E anymore we can close these tickets for now. Additionally, we can eventu... Vladan Cvejic