CIM Issues #6702
Grid Package: PhaseImpedanceData to support electrical parameters templates
61970-301
Description
In #5298, PhaseImpedanceData.fromPhase and PhaseImpedanceData.toPhase attributes have been removed. However, there is a use case for keeping those attributes, that is the use of line templates with electrical parameters. This is somewhat common on the distribution space. For example, find attached a screenshot of an Unbalanced line template in CYME where the entries of the matrix are specified using phases.
Files
Proposed Solution
(Re)add PhaseImpedanceData.fromPhase and PhaseImpedanceData.toPhase attributes and update the description of PhaseImpedanceData class accordingly.
Decision
19-Sep-2024 Joint TF Hybrid Meetings:
After discussing it is clear that we will need Celso to sound off with an explanation as to why the row and column cannot be used (i.e. the original reason we removed from/to is due to the many different approaches to exchanging this data. We moved to remove them to reduce the number of options)
Updated by Todd Viegut 10 months ago
- Status changed from New to Open
- Author/Contact Info set to Celso Rocha
- Solution to be Applied To set to CIM18v10
- CIM Impacted Groups WG14 added