Project

General

Profile

Issues #5906

sCnf51 at least one LPHD

Added by Richard Schimmel over 1 year ago. Updated over 1 year ago.

Status:
Rejected
Priority:
Normal
Due date:
09/06/2022 (about 19 months late)
Discuss in Upcoming Meeting:
No
Clause Reference:
8.2.5
61850 Standard:
7-1
Triggering Tissue:
Final Decision:
rejected
Initial Test Document:
Updated Test Document:
Test Case ID:
Closed Reason:
No Action Taken
Triggering Tissue 2:
Triggering Tissue 3:

Description

Part 7-1 clause 8.2.1 states "at least one LPHD" shall be available in a server device.

The sCnf51 test procedure requires:
"LPHD is present in each root logical device"

Propose to change into:
"LPHD is present in at least one root logical device"

and change the clause reference to 8.2.1

#1

Updated by IEC 61850 TPWG over 1 year ago

  • Due date set to 09/06/2022
  • Status changed from New to Resolved
  • Assignee set to Richard Schimmel
  • Closed Reason Test Procedure Update added
  • Closed Reason deleted (--Not Set---)

Update TP to at least one

#2

Updated by Joel Greene over 1 year ago

  • Status changed from Resolved to In Progress

Hmmm...

"LPHD is present in each root logical device" comes from 8.2.5 which defines root as not having GrRef.

#3

Updated by Richard Schimmel over 1 year ago

Indeed part 7-1 clause 8.2.5 is very specific: "LPHD shall be present in any root logical device". Propose to reject/close this issue, no change.

#4

Updated by Richard Schimmel over 1 year ago

  • Status changed from In Progress to Rejected
  • Clause Reference set to 8.2.5
  • Final Decision set to rejected
  • Test Case ID deleted (sCnf51)
  • Closed Reason No Action Taken added
  • Closed Reason deleted (Test Procedure Update)

Rejected, keep sCnf51 as is.

#5

Updated by IEC 61850 TPWG over 1 year ago

Reject confirmed

Also available in: Atom PDF