CIM Issues #5016
OperationalLimit for BranchGroupNeed a means to apply the
Status:
Open
Priority:
Normal
Author/Contact Info:
Kendall Demaree
Base Release:
CIM16
Solution to be Applied To:
Solution Version:
Solution Applied By:
Completion Date:
CIM Keywords:
Breaking Change:
No
Breaking Change Description:
CIM Impacted Groups:
WG13
Requestor:
Standard(s):
Version:
Clause:
Sub-Clause:
Paragraph:
Table:
Originally Closed in Version:
Origination Date:
10/18/2016
Origination ID:
13_270
Originally Assigned To:
Description
OperationalLimit for BranchGroup
Need a means to apply the general operational limit capabilities to BranchGroup rather than the fixed limit attributes on the BranchGroup class.
Proposed Solution
Suggest adding another optional association from OperationalLimitSet to BranchGroup. The direction on OperationalLimit type supplies the direction of flow relative to the BranchGroupTerminal direction.
Assign to Energy Model Requirements Subgroup
For additional information:
https://github.com/CIMug-org/WG13InformationModel/issues/9
Updated by Eric Stephan about 2 years ago
- Subject changed from OperationalLimit for BranchGroup Need a means to apply the to OperationalLimit for BranchGroupNeed a means to apply the
- Decision updated (diff)