CIM Issues #7002

Updated by Todd Viegut about 2 months ago

We've identified an issue with regards to constraint C:600:SV:SvStatus:SV__4.    It reads as follow: 

 "All state variables shall be instantiated in the SV instance file (distribution) for all energized elements part of a TopologicalIsland independently of the regulating status of the elements (e.g. for a shunt compensator that is not regulating the SvShuntCompensatorSections.sections shall be the same as ShuntCompensator.sections). 
 All instances shall be representing computed values obtained from a power flow calculation.  
 For SvPowerFlow instances refer to profile constraint on the SvPowerFlow class." 

 The way this was done for SvStatus in the current SHACL rule we output this error message: 

 "SvStatus is not instantiated for a ConductingEquipment connected to a TopologicalNode which is referenced by a TopologicalIsland." 

 *SvStatus*    is not instantiated for a *ConductingEquipment*    connected to a *TopologicalNode*    which is referenced by a *TopologicalIsland*. This does NOT make sense for the *BusbarSection* . BusbarSection. See proposed updates to the 456 and 600-2 publications. 




   