IEC 61970-600-1 General Requirements clause updates.

Added by Todd Viegut about 2 months ago. Updated about 2 months ago.

Status:
New
Priority:
Normal
Author/Contact Info:
Todd Viegut; todd.viegut@gmail.com
Base Release:
CIM17
Solution to be Applied To:
CIM18
Solution Version:
Solution Applied By:
Completion Date:
CIM Keywords:
Breaking Change:
Breaking Change Description:
CIM Impacted Groups:
WG13
Requestor:
Standard(s):

IEC 61970-600-1

Version:
Clause:
Sub-Clause:
Paragraph:
Table:
Originally Closed in Version:
Origination Date:
Origination ID:
Originally Assigned To:

Description

We have identified an issue in the IEC 61970-600-1 publication. In the General Requirements clause (i.e. specifically GENC12 & GENC13) it states constraint R:452:ALL:NA:exchange: “Optional and required attributes and associations must be imported and exported if they are in the distribution prior to import." However, TP as of CGMES 3.x is now output only profile and it is not required. During some vendor testing TopologicalIsland.description was not included in the exports. We need to file a clarification to ENTSO-E that this should potentially be revisited/clarified.

Note, we should probably double check 456 and CGMES SHACL constraints to see if those need updates as well.


Proposed Solution

Appropriate updates to the templates.