Project

General

Profile

CIM Issues #6456

Typo and old attributes present in 457 and 302

Added by Chavdar Ivanov about 1 year ago. Updated 9 months ago.

Status:
Closed
Priority:
Normal
Author/Contact Info:
Base Release:
CIM18v03
Solution to be Applied To:
18v05
Solution Version:
CIM18v05
Solution Applied By:
Chavdar Ivanov
Completion Date:
07/01/2023
CIM Keywords:
Breaking Change:
No
Breaking Change Description:
CIM Impacted Groups:
WG13
Requestor:
Standard(s):

61970-302, 61970-457

Version:
Clause:
Sub-Clause:
Paragraph:
Table:
Originally Closed in Version:
Origination Date:
05/10/2023
Origination ID:
Originally Assigned To:

Description

- WIndContQIEC2 shall be WindContQIEC2 – the change here is the 2nd letter not capital I but i. This is a typo in both 61970-302 and 61970-457
- In 61970-457 Table 511 (– Attributes of WindDynamicsEd2::WindContPType3IEC2) shall not have the following 2 rows (just delete them). These are leftovers from 2015 version of another IEC standard. The same attributes are present in another model in the standard
tpfiltp3 1..1 Seconds
Filter time constant for power measurement (Tpfiltp3) (>= 0). It is a type-dependent parameter.
tufiltp3 1..1 Seconds
Filter time constant for voltage measurement (Tufiltp3) (>= 0). It is a type-dependent parameter.

- In 61970-302 Table 586 (Attributes of WindDynamicsEd2::WindContPType3IEC2) shall not have the following 2 rows (just delete them). These are leftovers from 2015 version of another IEC standard. The same attributes are present in another model in the standard
tpfiltp3 0..1 Seconds Filter time constant for power measurement (Tpfiltp3) (>= 0). It is a type-dependent parameter.
tufiltp3 0..1 Seconds Filter time constant for voltage measurement (Tufiltp3) (>= 0). It is a type-dependent parameter.


Decision

Changes to be applied in FDIS version of 302 an 457


Release Notes

- WIndContQIEC2 shall be WindContQIEC2 – the change here is the 2nd letter not capital I but i. This is a typo in both 61970-302 and 61970-457
- In 61970-457 Table 511 (– Attributes of WindDynamicsEd2::WindContPType3IEC2) shall not have the following 2 rows (just delete them). These are leftovers from 2015 version of another IEC standard. The same attributes are present in another model in the standard
tpfiltp3 1..1 Seconds
Filter time constant for power measurement (Tpfiltp3) (>= 0). It is a type-dependent parameter.
tufiltp3 1..1 Seconds
Filter time constant for voltage measurement (Tufiltp3) (>= 0). It is a type-dependent parameter.

- In 61970-302 Table 586 (Attributes of WindDynamicsEd2::WindContPType3IEC2) shall not have the following 2 rows (just delete them). These are leftovers from 2015 version of another IEC standard. The same attributes are present in another model in the standard
tpfiltp3 0..1 Seconds Filter time constant for power measurement (Tpfiltp3) (>= 0). It is a type-dependent parameter.
tufiltp3 0..1 Seconds Filter time constant for voltage measurement (Tufiltp3) (>= 0). It is a type-dependent parameter.

#1

Updated by Chavdar Ivanov about 1 year ago

  • Status changed from New to Open
#2

Updated by Chavdar Ivanov about 1 year ago

  • Status changed from Open to Review
#3

Updated by Chavdar Ivanov about 1 year ago

  • Status changed from Review to Closed
#4

Updated by Chavdar Ivanov about 1 year ago

  • Standard(s) set to 61970-302, 61970-457
#5

Updated by Chavdar Ivanov about 1 year ago

  • Solution Version changed from 18v05 to CIM18v05
#6

Updated by Todd Viegut 9 months ago

  • Base Release changed from 18v03 to CIM18v03

Also available in: Atom PDF