CIM Issues #5893
CDPSM conflicting roles HydroPowerPlant.HydroPumps and HydroPump.HydroPowerPlant
Status:
Closed
Priority:
Normal
Author/Contact Info:
Base Release:
Solution to be Applied To:
Solution Version:
Solution Applied By:
Completion Date:
CIM Keywords:
Breaking Change:
Breaking Change Description:
CIM Impacted Groups:
WG13
Requestor:
Standard(s):
61968-13
Version:
2
Clause:
6.3.2.63
Sub-Clause:
Paragraph:
Table:
Originally Closed in Version:
Origination Date:
Origination ID:
Originally Assigned To:
Description
The role HydroPowerPlant.HydroPumps in section 6.3.2.63 is in conflict with the role HydroPump.HydroPowerPlant in section 6.3.2.64 because they are both roles of the same relationship
Proposed Solution
Given that model manager guidance usually promotes 0..1 roles over 0..* roles,
remove the role HydroPowerPlant.HydroPumps in section 6.3.2.63
and preserve the role HydroPump.HydroPowerPlant in section 6.3.2.64
Decision
19-Sep-2024 Joint TF Hybrid Meetings - Minneapolis:
Reviewed. Will be cleaned up when we regenerate the IEC 61970-452. Agreed we can close this out.