Project

General

Profile

Improvement #5089

Extension of CDC ASG

Added by Carlos Rodriguez del Castillo over 3 years ago. Updated over 1 year ago.

Status:
Resolved
Priority:
Normal
Assignee:
-
Category:
Standard extension required
Start date:
09/20/2021
Due date:
01/20/2022 (over 2 years late)
% Done:

0%

Estimated time:
ID:
13
Source:
MH
TF Unique ID:
13 # MH
WG10 Proposal:
Estimated Completion:
Discuss in Upcoming Meeting:
No
To discuss in WG10:
No
Short Proposal:
Standard(s):

IEC 61850 7-3 Ed2.1

Needs More Information:
No
Assigned TF:

Description

CDC ASG contains 'minVal' and 'maxVal' to limit the permissable value of 'setMag'. These values typically reflect the limits of the device application software.
Users require to create additional, more restrictive limit values, to be able to define application specific ranges. It shall be possible to define limit values different for each setting group.


Related issues

Copied to IEC TC57 WG10 Future Work - WG10 Future Work #5935: Extension of CDC ASGNew09/20/2021

Actions
#1

Updated by Carlos Rodriguez del Castillo almost 3 years ago

  • Status changed from New to Triage

minVal and maxVal are typically set and fixed by manufacturer's firmware. For example, for adaptative algorithm, we need to create new minVal and maxVal from application point of view to limit the setMag value, but there is no data attribute for that. The only solution today is to create new DOs in the LN to define this new limits. Some IEDs allow to change minVal and maxVal by LN instance, but you miss the valid limits and it is up to the ICT to handle it, so it is not a complete solution.
Discuss with Thierry Dufaure and Christoph Brunner the possibility of taking it into account for 61850-7-3 edition 3, because it implies an update of ASG CDC, and maybe it could be extended to others CDC.

#2

Updated by Carlos Rodriguez del Castillo over 2 years ago

  • Status changed from Triage to Resolved

This issue will be copied to "IEC TC57 WG10 Future Work" database to take into account in the future.
We recognize that the issue makes sense from the users perspective.

#3

Updated by Carlos Rodriguez del Castillo over 2 years ago

  • Discuss in Upcoming Meeting changed from Yes to No
#4

Updated by Vladan Cvejic over 2 years ago

#5

Updated by Carlos Rodriguez del Castillo over 1 year ago

  • Needs More Information set to No
#6

Updated by Carlos Rodriguez del Castillo over 1 year ago

  • Discuss in Upcoming Meeting changed from No to Yes
#7

Updated by Carlos Rodriguez del Castillo over 1 year ago

  • Discuss in Upcoming Meeting changed from Yes to No

Also available in: Atom PDF