- Added the following clarification to the EquivalentInjection description 

 Using EquivalentInjection to model a distribution network equivalent is recommended practice instead of using ExternalNetworkInjection-s if it is not necessary that the equivalent contains detailed information representing a short circuit equivalent according to IEC 60909 which is relevant for short circuit studies. 

 - Added the following clarification to the ExternalNetworkInjection description 
 It is only used if EquivalentInjection cannot provide the details required by IEC 60909 on short circuit equivalent of an external network.  

 - Modeified the following statement in the Equipment.aggregate to include ExternalNetworkInjection. The revised version is: 
 The attribute is not used for EquivalentBranch, EquivalentShunt, EquivalentInjection and ExternalNetworkInjection. 

 - Deleted the folling constraint from 452 
 • 	 C:452:EQ:EquivalenInjection:instance 
 Using EquivalentInjection to model a distribution network equivalent is recommended practice instead of using ExternalNetworkInjection-s.