CIM Issues #6612
Missing association in Dynamics package
Description
The following comment was submitted by the National committees during FDIS voting for IEC 61970-302 and IEC 61970-457
“StatorCurrentLimiterDynamics class is missing the link to the ExcitationSystemDynamics in similar way as it is done for other classes. Please consider fixing this issue in the FDIS process as otherwise it is not possible to link this controller model to the corresponding synchronous generator. We believe this occurred due to editorial modifications.”
Proposed Solution
Add requested association
Decision
Based on the FDIS voting the association StatorCurrentLimiterDynamics.ExcitationSystemDynamics should be added with cardinality 0..1 and 1..1
Release Notes
Changes in Dynamics package in IEC 61970-302 and in the DY profile in IEC 61970-457
- StatorCurrentLimiterDynamics.ExcitationSystemDynamics association added with cardinality 0..1 and 1..1