Project

General

Profile

Issues #644

The test procedures does not specify which test cases are applicable for variants

Added by Richard Schimmel about 3 years ago. Updated almost 2 years ago.

Status:
Closed
Priority:
Normal
Assignee:
-
Due date:
Discuss in Upcoming Meeting:
No
Clause Reference:
3.2 of the test procedure
61850 Standard:
Triggering Tissue:
Final Decision:
Agree to add: All configuration file and data model tests have been successfully performed for the product variants
Initial Test Document:
Test Case ID:
general
Closed Reason:
Test Procedure Update
Triggering Tissue 2:
Triggering Tissue 3:

Description

The Dutch accreditation council reviewed the test report and commented the test report does not specify which tests are executed on the variants. It is specified on the certificate. Proposal: Copy the variant sentence from the certificate into the test report in clause 3.2

#1

Updated by Richard Schimmel about 3 years ago

  • Status changed from Accepted to In Progress
  • Final Decision set to Agree to add: All configuration file and data model tests have been successfully performed for the product variants

TPWG: Agree to add the bold sentence to clause 3.2:

The PICS is used to select the applicable test procedures to be included in the test.

All configuration file and data model tests have been successfully performed for the product variants

#2

Updated by Richard Schimmel about 3 years ago

  • Status changed from In Progress to Resolved
#3

Updated by Bruce Muschlitz about 3 years ago

TPWG 20210309: TPWG agrees with proposal to add text to test report template

#4

Updated by Bruce Muschlitz almost 3 years ago

  • Status changed from Resolved to Closed
  • Updated Test Document set to ucatestproceduresserver61850-8-1ed2_rev2p0p5.pdf
  • Closed Reason Test Procedure Update added
#5

Updated by Bruce Muschlitz almost 2 years ago

  • Discuss in Upcoming Meeting changed from Yes to No

Also available in: Atom PDF