Project

General

Profile

CIM Issues #6461

Updated by Chavdar Ivanov about 1 year ago

The following attributes are added to 302 and 457 as required attributes in simulation settings profile 
 - maxIterationsInnerLoop, integer, Description: Maximum iterations of inner loop of the power flow calculation algorithm inner loop. algorithm.   
 - maxIterationsOuterLoop, integer, Description: Maximum iterations of outer loop of the power flow calculation algorithm outer loop. algorithm. This can refer to the maximum number of iterations when area interchange control is performed as part of an outer loop or when specific control actions are done in the outer loop. used. 
 - loadResponseCharacteristicsEnabled, boolean, Description: True means load response characteristics are considered, if present in the model. False, means that even if enabled, the load response characteristics are not taken into account by the power flow calculation algorithm.

Back