Updated by Chavdar Ivanov almost 2 years ago
Applied the following changes
Change to the NonlinearShuntCompensatorPoint:
b is replaced with bTotal: Total positive sequence shunt (charging) susceptance at section noted by sectionNumber.
b0 is replaced with b0Total: Total zero sequence shunt (charging) susceptance at section noted by sectionNumber.
g is replaced with gTotal: Total positive sequence shunt (charging) conductance at section noted by sectionNumber.
g0 is replaced with g0Total: Total zero sequence shunt (charging) conductance at section noted by sectionNumber.
Modified the description of the NonlinearShuntCompensator to refere to the new attributes
Modified EQ and SC profiles in 61970-452.