Project

General

Profile

Issues

Filters

Apply Clear

# Project Tracker ID Source Status Priority Standard(s) Subject Updated
5970 IEC 61850 User Feedback Task Force Improvement 2022 f2F IOP In Progress Normal

IEC 61850-6

SCT behavior needs to be specified regarding mismatch between substation section and IED section 11/08/2022 08:24 AM Actions
5968 IEC 61850 User Feedback Task Force Improvement Resolved Normal Change the diagrams in 7-500 to not use yellow lines 06/05/2023 01:58 AM Actions
5955 IEC 61850 User Feedback Task Force Improvement EDF Resolved Normal Indicate typical SIUnit for every DO with CDC MV would help users + Add a dedicated attribute in NSD files instead of having it in the description ? 06/05/2023 01:58 AM Actions
5921 General Testing Issues Improvement Resolved Normal Start using Vendor and Lab Submission Information 09/06/2022 09:33 AM Actions
5876 IEC 61850 User Feedback Task Force Improvement FNN Germany Resolved Normal

IEC 61850-7-4 Ed.3

Proposal of a new LN class ASWI 06/05/2023 01:58 AM Actions
5372 IEC 61850 User Feedback Task Force Improvement RTE Resolved Normal

IEC 61850-7-1

Simultaneous change of InRef.setSrcRef and InRef.setSrcCB for dynamic commutation 06/05/2023 01:58 AM Actions
5335 IEC 61850 User Feedback Task Force Improvement Dustin Tessier Resolved Normal

IEC 61850-90-4

Adding Normative Requirements & Conformance Testing Pertaining to Broadcast Storms 06/05/2023 01:58 AM Actions
5330 IEC 61850 User Feedback Task Force Improvement SCL IOP 2021 Resolved Normal

IEC 61850-90-30

LNode iedName attribute usage needs to be clarified 06/05/2023 01:58 AM Actions
5329 IEC 61850 User Feedback Task Force Improvement SCL IOP 2021 Resolved Normal

IEC 61850-6

Clarify iedType attribute usage in DataTypeTemplates 06/05/2023 01:58 AM Actions
7158 Client Issues New Normal GetDataValues and SetDataValues Services 03/11/2025 10:19 PM Actions
7156 Client Issues New Normal Definition for 'Supporting Substitution Service' 03/11/2025 09:31 AM Actions
7154 Server Issues New Normal sDoc5 Services SMVsc condition is missing "publisher" 03/05/2025 03:50 AM Actions
7131 Server Issues In Progress Normal Update sGop13 test case with PIXiT max attributes 03/05/2025 04:02 AM Actions
7128 Server Issues In Progress Normal Reconfiguration of a LGOS / LSVS prefix instance number in SCT test is missing 03/05/2025 04:12 AM Actions
7125 Server Issues In Progress Normal sCnf test procedures are not listed on certificates 03/05/2025 02:27 AM Actions
7123 Server Issues Resolved Normal sSvs12 according to PIXIT-Svs4 verifying ConfRev is optional 02/18/2025 08:36 AM Actions
7101 Server Issues Resolved Normal sLog13 is LCB.LogRef always writable (SCL Services LogSettings has no attribute for LogRef) 03/04/2025 08:13 AM Actions
7100 Server Issues Resolved Normal Tissue 1934 Subscriber with beh=on receives GOOSE with q.test=true, then subscriber changes to test mode. 03/14/2025 05:49 AM Actions
7097 Server Issues Resolved Normal Step number error in expected result of sGos6b in Rev1.3 test procedure 01/21/2025 08:08 AM Actions
7091 Server Issues Rejected Normal sSrv17 - New value should be different from the previous one and not from the SCL value. Test case will not work twice with SPG setpoints. 01/21/2025 08:06 AM Actions
7089 Server Issues Resolved Normal sMdl4, sMdl6 and sMdl15 not possible for SV only device 01/21/2025 08:06 AM Actions
7084 Server Issues Resolved Normal sTmP5 clarify the format of LTMS.TmsSrc = GMCID 01/07/2025 08:50 AM Actions
7083 Server Issues Resolved Normal sLog6 to sLog9 too many steps in one detailed test procedure 01/21/2025 08:09 AM Actions
7082 Server Issues Rejected Normal sCnf121 requires to use lnNs for the 61869-9 extensions 01/07/2025 08:59 AM Actions
7074 Server Issues Resolved Normal Update chapter 1.1 identifications table to have SCT simulator information 01/21/2025 08:14 AM Actions
(101-125/2322) Per page: 25, 50, 100