# Project Tracker ID Source Status Priority Standard(s) Subject Updated
6454 CIM Issues CIM Issues New Normal

61970-301

RemoteUnit minor typo in 301 description 06/28/2023 04:27 PM Actions
6408 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification of addCause 06/20/2023 08:37 AM Actions
6407 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - allow 3 values per time point 06/20/2023 08:36 AM Actions
6406 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - add optional data objects to support irregular interval schedules 06/20/2023 08:36 AM Actions
6405 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Schedules - allow updates to single values while schedules are running 06/20/2023 08:35 AM Actions
5979 WG14 Part 9 Issues CIM Issues New Normal

IEC 61968-9 and others

Meter to UsagePoint relationship should be many-to-many 06/15/2023 09:32 AM Actions
6387 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal S/S related applications: Auxiliary circuit supervision 06/14/2023 08:20 AM Actions
6386 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Voltage protection: Overvoltage protection - 3ph operate 06/14/2023 08:20 AM Actions
6385 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Voltage protection: Undervoltage protection - 3ph operate 06/14/2023 08:19 AM Actions
6384 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal New controllable DO in RREC to define the mode of the recloser of the circuit breaker 06/14/2023 08:19 AM Actions
6383 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Single phase and multi phase trip indication for the autorecloser 06/14/2023 08:19 AM Actions
6382 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 1/3 06/14/2023 08:18 AM Actions
6380 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 2/3 06/14/2023 08:18 AM Actions
6379 61850-7-5 and 61850-7-500 IEC61850-7-5 New Normal Clarification on the ctlModel 3/3 06/14/2023 08:17 AM Actions
6377 61850-7-5 and 61850-7-500 IEC61850-7-5 New High Update the Switchgear / Breaker Model 06/14/2023 08:17 AM Actions
5295 CIM Joint Issues CIM Issues New Normal

61968-11, 61968-4, 61970-301, 61968-13

Joint issue on ACLineSegment physical modeling clarification 06/13/2023 09:06 AM Actions
6372 CIM Joint Issues CIM Issues New High Inconsistencies in Nameplate data for DERs 06/12/2023 08:18 AM Actions
6368 WG14 Part 9 Issues CIM Issues New High

61968-9

The interplay between events and status measurements should be supported more cleanly 06/01/2023 11:03 AM Actions
6367 WG14 Part 9 Issues CIM Issues New Normal

61968-9

Prepay Metering 06/01/2023 08:51 AM Actions
6322 WG14 Part 9 Issues CIM Issues New Normal

61968-9

New "Low Loss Potential" Quality Code needed in Part 9 06/01/2023 08:37 AM Actions
6296 WG14 Part 9 Issues CIM Issues New Normal

61968-9

New "Transformer Compensated" Quality Code needed in Part 9 06/01/2023 08:10 AM Actions
5950 WG14 Part 9 Issues CIM Issues New Normal

61968-9, 61968-11

How is readCycle used, should the definition be updated? 05/31/2023 07:13 PM Actions
6297 WG14 Part 9 Issues CIM Issues New Normal

61968-9

New Event code needed in Part 9 for DC Voltage 04/20/2023 09:54 AM Actions
6321 CIM Issues CIM Issues New Normal Update the description of MktActivityRecord 04/20/2023 03:46 AM Actions
6298 WG14 Part 9 Issues CIM Issues New Normal

61968-9

New Event codes needed in Part 9 for overvoltage and undervoltage 03/22/2023 08:48 AM Actions
(76-100/2206) Per page: 25, 50, 100