Project

General

Profile

Issues

Filters

Apply Clear

# Project Tracker ID Source Status Priority Standard(s) Subject Updated
6630 WG13 Issues CIM Issues Open Normal

61970-301

Update Identity and naming description 09/04/2024 10:51 AM Actions
6616 WG13 Issues CIM Issues Open Normal

61970-301; 61970-452

Add SubstationKind 09/04/2024 10:51 AM Actions
6553 WG13 Issues CIM Issues Open High Removal of InfGrid package InfSIPS 09/04/2024 10:51 AM Actions
6357 WG13 Issues CIM Issues Open Normal

61970-301, 61970-452, 61968-13

[GMDM #9] Modeling behind the inverter 09/04/2024 10:51 AM Actions
6345 WG13 Issues CIM Issues Open Normal

61970-301, 61970-452, 61968-13

[GMDM #13] Overhead / underground indicator on equipment 09/04/2024 10:50 AM Actions
6344 WG13 Issues CIM Issues Open Normal

61970-301, 61970-452, 61968-13

[GMDM #10] Add .orderedPhases attribute on LinearShuntCompensatorPhase 09/04/2024 10:50 AM Actions
6329 WG13 Issues CIM Issues Open High

IEC61970-301, IEC61970-456

VsConverter required and optional attributes in SSH and SV Profiles 09/04/2024 10:49 AM Actions
6328 WG13 Issues CIM Issues Open High

IEC 61970-301, IEC 61970-452, IEC 61070-600

Required usage of BusbarSection 09/04/2024 10:49 AM Actions
6247 WG13 Issues CIM Issues Open Normal

61970-301

Missing support for fault indicators 09/04/2024 10:49 AM Actions
6178 WG13 Issues CIM Issues Open Low Relation between ResourcePerformanceEvaluation and ResourcePerformanceGlobalFactor contains a typo at the source side (role) of the association. 09/04/2024 10:49 AM Actions
5978 WG13 Issues CIM Issues Open Normal

61968-301

Remove serialization instructions from the UML description of mRID 09/04/2024 10:49 AM Actions
5977 WG13 Issues CIM Issues Open Normal

61968-13, 61968-11, 61970-600-2

Cardinality of PowerSystemResource to Location 09/04/2024 10:48 AM Actions
5971 WG13 Issues CIM Issues Open Low CIM-61850 Harmonization - Consider modelling fans, pump motors and battery systems as types of auxiliary equipment 09/04/2024 10:47 AM Actions
5897 WG13 Issues CIM Issues Open Normal

61968-13

CDPSM Substation.Station and Substation.SupplyingStation 09/04/2024 10:47 AM Actions
6811 WG13 Issues CIM Issues Open Normal

IEC61970-301

Clean up Equivalent modelling descriptions and classnames 09/04/2024 10:46 AM Actions
6809 WG13 Issues CIM Issues Open Normal

IEC 61970-301

Migrate approved Ext* Protection Equipment and Network Code extensions into normative CIM 09/04/2024 10:46 AM Actions
6807 WG13 Issues CIM Issues Open Normal

IEC 61970-301

Add classes for EV, Electric Vehicle Supply Equipment, Charging Station, Charging Park, Charging Zone 09/04/2024 10:45 AM Actions
6800 WG13 Issues CIM Issues Open Normal Ambiguous associations between RelayDynamics and ConductingEquipment(end role name = ProtectedEquipment) and ProtectionEquipment (end role name = ProtectedEquipment) 09/04/2024 10:45 AM Actions
6773 WG13 Issues CIM Issues Open Normal

IEC61970-301, IEC61970-452

DC device containment rules need to be updated 09/04/2024 10:45 AM Actions
6713 WG13 Issues CIM Issues Open Normal Update namespace and profile from http to https 09/04/2024 10:44 AM Actions
6822 WG13 Issues CIM Issues Open Normal Why are WindTurbineType1or2Dynamics models required to link to another AsynchronousMachineDynamics model rather than directly associating with the AsynchronousMachine? 09/04/2024 10:44 AM Actions
6831 WG13 Issues CIM Issues Open Normal ProductAssetModel.weightTotal and SwitchInfo.gasWeigthPerTank have type Mass as a string and not as a link to CIMDataType Mass 09/04/2024 10:44 AM Actions
6872 WG13 Issues CIM Issues Open Normal

IEC 61970-456, IEC 61970-450

Make TP easier to compare 09/04/2024 10:43 AM Actions
6873 WG13 Issues CIM Issues Open Normal

IEC 61790-456

Create support for fault and unsolved solution 09/04/2024 10:43 AM Actions
6889 WG13 Issues CIM Issues Open High Modelling of composite loads 09/04/2024 10:42 AM Actions
(51-75/2194) Per page: 25, 50, 100

Also available in: Atom CSV PDF