Project

General

Profile

CIM Issues #5896

CDPSM conflicting roles RotatingMachine.HydroPump and HydroPump.RotatingMachine

Added by Martin Miller over 1 year ago.

Status:
New
Priority:
Normal
Author/Contact Info:
Base Release:
Solution to be Applied To:
Solution Version:
Solution Applied By:
Completion Date:
CIM Keywords:
Breaking Change:
Breaking Change Description:
CIM Impacted Groups:
WG13
Requestor:
Standard(s):

61968-13

Version:
2
Clause:
6.3.2.112
Sub-Clause:
Paragraph:
Table:
Originally Closed in Version:
Origination Date:
Origination ID:
Originally Assigned To:

Description

The role RotatingMachine.HydroPump in section 6.3.2.112 is in conflict with the role HydroPump.RotatingMachine in section 6.3.2.64 because they are both roles of the same relationship


Proposed Solution

Given that both CPSM and CGMES have chosen to implement the 1..1 role HydroPump.RotatingMachine instead of the 0..1 role and it is desirable to maintain consistency across profiles,
remove the role RotatingMachine.HydroPump in section 6.3.2.112
and preserve the role HydroPump.RotatingMachine in section 6.3.2.64

No data to display

Also available in: Atom PDF