Project

General

Profile

CIM Issues #5836

Instructions.instructionStartTime update description

Added by Herbert Falk almost 2 years ago. Updated over 1 year ago.

Status:
Closed
Priority:
Normal
Author/Contact Info:
Becky
Base Release:
iec61970cim17v34_iec61968cim13v12_iec62325cim04v08
Solution to be Applied To:
Solution Version:
iec61970cim17v34_iec61968cim13v12_iec62325cim04v10
Solution Applied By:
BLI
Completion Date:
02/10/2022
CIM Keywords:
Breaking Change:
Breaking Change Description:
CIM Impacted Groups:
None
Requestor:
Standard(s):
Version:
Clause:
Instructions
Sub-Clause:
Paragraph:
Table:
Originally Closed in Version:
Origination Date:
01/18/2022
Origination ID:
16_0120
Originally Assigned To:

Description

instructionStartTime description should be enhanced to include the use of the Instructions class for instructions that may deploy a resource for a demand side event, or release a resource or adjust a resource.


Proposed Solution

instructionStartTime description
currently:
Time the resource should be at Pmin (for start ups).
Time the resource is off line.

proposal:
The date/time at which the resource should achieve the Dispatch Operating Target (DOT). Unless otherwise specified in earlier instructions, any ramping should be performed in advance of the instructionStartTime. The resource is expected to maintain the DOT until either a subsequent instruction is received or instructionClearing interval ends.


Decision

2/10/2022: Team agreed to updates

#1

Updated by Becky Iverson over 1 year ago

  • Status changed from New to Closed
  • Proposed Solution updated (diff)

Also available in: Atom PDF