Description
Text corrections for SvInjection
1) SvInjection.pNetInjection
old: "The activive power injected into the bus at this location."
suggested: "The activive power injected into the bus at this location. Positive sign means injection into the bus."
2) SvInjection.qNetInjection
old: "The activive power injected into the bus at this location." (wrong!)
suggested: "The reactivive power injected into the bus at this location. Positive sign means injection into the bus."
Proposed Solution
Also add the following to description
Positive sign means flow into the TopologicalNode.
Decision
Updated as proposed