Redmine WG14 Part 3 Issues - CIM Issues #6744 (New): CrewStatusKind enumeration is missing values for dea...https://redmine.ucaiug.org/issues/67442024-03-26T16:56:48ZMartin Millermartin.miller@glires.com
<p>The current CrewStatusKind enumeration only contains entries for assignment of crews and the only value (fieldComplete) that represents the deassignment of a crew also represents the completion of work. It is missing any entries that represent the deassignment of a crew without completement of work.</p>
<p>At a minimum the enumeration needs an additional value to represent the concept of "Deassigned" which means that "the crew is no longer working on the outage in the field, without the outage being corrected". <br />Ideally, there would also be a second additional value to represent the concept of "Rejected" which means that "the crew has refused an assignment."</p> IEC 61850 Certificate - IEC 61850 Certificate #6742 (Approved): V321 Arc Flash Protection Systemhttps://redmine.ucaiug.org/issues/67422024-03-24T19:15:30ZHerbert FalkIEC 61850 Certificate - IEC 61850 Certificate #6741 (Approved): SA-G3000https://redmine.ucaiug.org/issues/67412024-03-24T19:09:32ZHerbert FalkIEC 61850 Certificate - IEC 61850 Certificate #6740 (Approved): ALARM ANNUNCIATOR MBAS 0600https://redmine.ucaiug.org/issues/67402024-03-24T18:50:11ZHerbert Falk
<p>MBAS 0600 Microprocessor/ Microcontroller Based Alarm Annunciator is designed to keep an alert and watchful eye on plant and processes. It is equipped with super bright LED facia windows , site selectable, programmed sequences as per ISA standard and optional customize sequences.</p> IEC 61850 User Feedback Task Force - Feature #6739 (New): How to deal with 'Beh' and 'Health' of ...https://redmine.ucaiug.org/issues/67392024-03-18T10:37:35ZMichael Haecker
<p>For site testing, users shall use the test mode to isolate devices/functions to prevent from flooding control centres with test data.</p>
<p>Whereas data marked "test" can be filtered out, changes of 'Beh' cannot be filtered out. When, for example, changing the active parameter set, the user will create data towards the control centre for LN instances which are activated/inactivated through this change.<br />[Part 7-4 Annex A: "Regardless of the status of LN.Beh, the quality test attribute of Mod, Beh and Health shall be q.test=false."]</p>
<p>In an automation system where a gateway is used to interface the control centre, this gateway could implement a feature to block the information flow of a device in test. Where a direct link via IEC 61850 is used, such blocking is not possible.</p> IEC 61850 User Feedback Task Force - Improvement #6738 (New): Amending TGSN LN class with setting...https://redmine.ucaiug.org/issues/67382024-03-18T10:14:44ZMichael Haecker
<p>The LN classes TCTR and TVTR inherit from 'InstrumentTransformerLN' some settings which can be used for adapting the output signal.</p>
<p>TGSN LN class is missing the settings for scaling, linerarization, wideing of a focussed range.</p> IEC 61850 User Feedback Task Force - Bug #6737 (New): Amending TGSN LN class with signal characte...https://redmine.ucaiug.org/issues/67372024-03-18T09:57:10ZMichael Haecker
<p>The model of a generic sensor does not provide characteristics about the analogue signal type which is used to receive the sensor value.</p>
<p>TC57/WG18 are proposing to amend the model with a setting to state the analogue signal type.</p> WG13 Issues - CIM Issues #6736 (New): Quality61850 Class does not match the definition of Quality...https://redmine.ucaiug.org/issues/67362024-03-12T21:05:03ZTom Berry
<p>CIM definition is missing Inconsistent, Inaccurate Boolean<br />IEC 61850 does not define Source = DEFAULTED</p>
<p>Encoding is now<br />/*
* Bit(s) Name Value<br /> 0-1 Validity Good 0 0<br /> Invalid 0 1<br /> Reserved 1 0<br /> Questionable 1 1<br /> 2 Overflow<br /> 3 OutofRange<br /> 4 BadReference<br /> 5 Oscillatory<br /> 6 Failure<br /> 7 OldData<br /> 8 Inconsistent<br /> 9 Inaccurate<br /> 10 Source Process 0<br /> Substituted 1<br /> 11 Test<br /> 12 OperatorBlocked<br /> */</p> WG16 Issues - CIM Issues #6735 (New): new disclaimer note on every Inf* UML diagram indicating to...https://redmine.ucaiug.org/issues/67352024-03-11T19:54:31ZBecky Iverson
<p>We need to indicate the usage of Inf in a more explicit way to avoid confusions.</p> WG16 Issues - CIM Issues #6734 (New): Review use/inheritance of Document by UCA TF 16 classes, pr...https://redmine.ucaiug.org/issues/67342024-03-11T14:58:20ZBecky Iverson
<p>UTF 14 is reviewing all classes that are inheriting from Document and has request UTF 16 to review the use of Document class.</p> IEC 61850 Certificate - IEC 61850 Certificate #6733 (Approved): ETLID1000https://redmine.ucaiug.org/issues/67332024-03-11T13:38:57ZHerbert FalkIEC 61850 Certificate - IEC 61850 Certificate #6732 (Approved): ETMDU1000https://redmine.ucaiug.org/issues/67322024-03-11T13:34:32ZHerbert FalkWG13 Issues - CIM Issues #6632 (New): update definition of deprecatedhttps://redmine.ucaiug.org/issues/66322023-12-11T10:49:27ZSvein Olsen
<p>IEC 61970-301 defines <<deprecated>> as:<br />“4.7.5 Deprecations<br />The CIM model may at times contain packages, classes, attributes, or associations that have been identified as deprecated. These items will be noted in the documentation or with a UML stereotype of “deprecated”. A deprecated item is retained in the present version of the model, but is expected to be removed from future versions. An item that has not been deprecated is not guaranteed to be retained in future versions, but using an item marked as deprecated should be avoided if possible."</p> WG13 Issues - CIM Issues #6452 (In Progress): Allow multiple RatioTapChanger on one TransformerEndhttps://redmine.ucaiug.org/issues/64522023-06-28T15:04:20ZYang Feng
<p>The current cardinality only allows one RatioTapChanger to be associated to a PowerTransformerEnd. I've come across multiple scenarios where a transformer may have two RatioTapChanger on one PowerTransformerEnd, one of which is on-load tap changer and the other one is off-load tap changer. Attached I've added one example from a real customer data describing it.</p> WG14 Issues - CIM Issues #5237 (Review): Eliminate compoundshttps://redmine.ucaiug.org/issues/52372022-01-13T12:39:38ZHerbert Falk
<p>Eliminate use of compound classes street address, street detail, electronic address, telephone number (2)</p>